Honeywell Home Security System VISTA 128FBP User Manual

VISTA-128FBP  
VISTA-250FBP  
Commercial Fire and Burglary  
Partitioned Security Systems  
with Scheduling  
User Guide  
K0377V2 7/09 Rev. B  
 
TABLE OF CONTENTS  
SYSTEM OVERVIEW ............................5  
Using the ✴  
READY Key.................28  
General.......................................................5  
A Partitioned System ..................................5  
Zones..........................................................6  
Fire Protection ............................................6  
Burglary Protection .....................................6  
Carbon Monoxide Protection......................7  
Alarms.........................................................7  
Memory of Alarm ........................................7  
Using Schedules.........................................7  
Device Timers.............................................8  
To Access another Partition (GOTO  
DISPLAYING ALL ZONE  
DESCRIPTORS.................................29  
Using the READY Key......................29  
BYPASSING PROTECTION ZONES....30  
Using the 6 BYPASS Key....................30  
Quick Bypass............................................31  
Displaying Bypassed Zones .....................31  
Group Bypass...........................................32  
ARMING PERIMETER ONLY...............33  
Command)..................................................8  
Master Keypad Operation...........................8  
Self-Help Feature........................................9  
ABOUT THE KEYPADS.......................10  
General.....................................................10  
The Alpha Keypad ....................................10  
FUNCTIONS OF THE KEYPAD...........11  
ENTRY/EXIT DELAYS .........................15  
General Information..................................15  
SECURITY CODES AND  
Using the 3 STAY key..........................33  
Auto-STAY Arming ...................................34  
ARMING PERIMETER ONLY...............35  
Using the 7 INSTANT Key...................35  
ARMING ALL PROTECTION................36  
Using the 2 AWAY Key........................36  
ARMING ALL PROTECTION................37  
Using the 4 MAXIMUM Key.................37  
QUICK EXIT .........................................38  
Using the # + 9 Keys.......................38  
AUTHORITY LEVELS.......................16  
General Information..................................16  
Duress Code.............................................16  
Quick Arming ............................................16  
Authority Levels ........................................17  
General Rules on Authority Levels and  
DISARMING AND SILENCING  
ALARMS............................................39  
Changes ...................................................18  
To Exit User Edit Mode.............................18  
To Add a User...........................................19  
To Change a User's Code ........................21  
To Delete a User.......................................22  
ACCESSING OTHER PARTITIONS.....23  
To Access another Partition .....................23  
Global Arming...........................................23  
Master Keypad Operation.........................24  
Common Lobby Operation .......................26  
How User Codes Affect the Common  
Using the 1 OFF Key ...........................39  
Memory of Alarm ......................................39  
USING THE KEYSWITCH ....................40  
General.....................................................40  
Arming ......................................................40  
Disarming..................................................40  
CHIME MODE ......................................41  
Using the 9 Key ...................................41  
VIEWING ALARM COMPANY  
MESSAGES ......................................42  
General Information..................................42  
Lobby........................................................27  
CHECKING FOR OPEN ZONES..........28  
– 3 –  
 
PANIC KEYS ....................................... 43  
Using Panic Keys .....................................43  
RELAY CONTROL............................... 44  
General Information..................................44  
Executing..................................................44  
USING #70 RELAY MENU MODE ....... 45  
General Information..................................45  
USING SCHEDULES........................... 46  
Delaying the Closing Time .......................46  
Temporary Open/Close Schedules ..........46  
Programming Temporary Schedules .......47  
PROGRAMMING DEVICE TIMERS..... 49  
General Information..................................49  
Randomize Output Device Times.............51  
USING #77 INSTANT ACTIVATION  
FIRE ALARM SYSTEM ........................58  
In Case Of Fire Alarm...............................58  
Silencing a Fire Alarm ..............................58  
Event Display Lock...................................59  
Fire Drill Test (Code + # + 69)..................59  
TROUBLE CONDITIONS .....................60  
Typical Trouble Displays ..........................60  
Power Failure ...........................................61  
EMERGENCY EVACUATION ..............62  
MAINTAINING YOUR SYSTEM ...........63  
Taking Care of Your System ....................63  
Replacing Batteries in Wireless  
Sensors ....................................................63  
Silencing Low Battery Warning Tones  
at the Keypad ...........................................64  
Routine Care ............................................64  
QUICK GUIDE TO FIRE SYSTEM  
MODE............................................... 52  
EVENT LOG PROCEDURES............... 55  
General Information..................................55  
To Display The Event Log........................55  
TESTING THE SYSTEM (TO BE  
FUNCTIONS .....................................65  
QUICK GUIDE TO BURGLARY  
SYSTEM FUNCTIONS......................66  
SUMMARY OF AUDIBLE  
NOTIFICATION.................................68  
INDEX ..................................................73  
CONDUCTED WEEKLY).................. 57  
Using the 5 TEST Key.........................57  
Testing Your System ................................57  
4 –  
 
System Overview  
General  
Congratulations on your ownership of a Honeywell partitioned Security  
System. You've made a wise decision in choosing it, for it represents the  
latest in security protection technology today. Honeywell is the world's  
largest manufacturer of security systems and millions of premises are  
protected by Honeywell systems.  
This system offers you three forms of protection: burglary, fire and  
emergency. To realize the system's full potential, it is important that you feel  
comfortable in operating it. Your system consists of at least one Keypad  
which provides full control of system operation, various sensors which  
provide perimeter and interior burglary protection, plus a selected number of  
strategically placed smoke or combustion detectors designed to provide early  
warning in case of fire.  
The system uses microcomputer technology to monitor all protection zones  
and system status and provides appropriate information for display on the  
Keypad(s) used with the system, and initiates appropriate alarms. Your  
system may also have been programmed to automatically transmit alarm or  
status messages over the phone lines to a central alarm monitoring station.  
NOTE: All references in this manual for number of zones, number of  
user codes, and the event log capacity, use the VISTA-250FBP’s  
features. The following table lists the differences between the  
VISTA-128FBP and the VISTA-250FBP control panels. All other  
features are identical for both panels.  
Feature  
Number of Zones  
VISTA-128FBP  
VISTA-250FBP  
128  
150  
512  
250  
250  
Number of User Codes  
Event Log Capacity  
1000  
A Partitioned System  
Simply stated, a partitioned system shares one physical alarm system among  
different users, each with their own requirements. For the most part, you as  
a user need not know about other users and their structure in the system,  
but from time to time, you may see display messages that indicate the system  
is in use by another user. Do not be concerned as this is normal. Refer to the  
ACCESSING OTHER PARTITIONS section for additional information.  
5 –  
 
System Overview (contd)  
Zones  
Your system's sensing devices have been assigned to various "zones." For  
example, the sensing device on your Entry/Exit door may have been assigned  
to zone 001, sensing devices on windows in the master bedroom to zone 002,  
and so on. These numbers will appear on the display, along with an alpha  
descriptor for that zone (if programmed), when an alarm or trouble condition  
occurs.  
Fire Protection  
The fire protection portion of your security system (if used) is always on and  
will sound an alarm if a fire condition is detected. Refer to the Fire Alarm  
System section for important information concerning fire protection, smoke  
detectors and planning emergency exit routes from your facility.  
Burglary Protection  
The burglary protection portion of your system must be turned on or "armed" before it  
will sense burglary alarm conditions. Your system provides four modes of burglary  
protection: STAY, AWAY, INSTANT and MAXIMUM, and even allows you to  
BYPASS selected zones of protection while leaving the rest of the system armed. The  
system also provides a CHIME mode, for alerting users to the opening and closing of  
doors and windows while the system is disarmed. Refer to the other sections of this  
manual for procedures for using these features.  
The following table lists the four different arming modes and the results of each.  
Features For Each Arming Mode  
Arming Mode  
AWAY  
STAY✳  
INSTANT✳  
MAXIMUM  
Exit Delay  
Entry Delay  
Perimeter Armed  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
No  
The system provides three different STAY and INSTANT arming modes. See  
ARMING IN THE STAY MODES and ARMING IN THE INSTANT MODES  
sections for details on these modes.  
6 –  
 
System Overview (contd)  
Carbon Monoxide Protection  
Carbon monoxide (CO) protection is available with your system using the 5800CO  
Carbon Monoxide Detector. The 5800CO is a 3V battery powered wireless Carbon  
Monoxide Detector used with wireless alarm systems that support 5800 series  
devices. Carbon monoxide gas is a highly poisonous gas which is released when fuels  
are burned. It is invisible, has no smell and is therefore impossible to detect with the  
human senses. We strongly suggest installing Carbon monoxide protection with your  
system.  
Alarms  
When an alarm occurs, both the keypad and external sounders will sound, and the  
keypad will display the zone(s) causing the alarm. If your system is connected to a  
central monitoring station, an alarm message will also be sent. To stop the alarm  
sounding, simply disarm the system.  
Memory of Alarm  
When an alarm condition occurs, the keypad displays the number(s) of the zone(s)  
that caused the problem, and displays the type of alarm (ex. FIRE, ALARM). It  
remains displayed until it is cleared by disarming the system (see Disarming the  
System section).  
Using Schedules  
Your system may have been programmed with schedules for automatically  
arming, disarming and activating various devices and/or performing other  
system functions at predetermined times. Users can modify some of these  
schedules by manually delaying a closing time, using temporary schedules, or  
by programming special user schedules. Refer to the Using Schedules section  
at the end of this manual for scheduling related procedures.  
7 –  
 
System Overview (contd)  
Device Timers  
The system provides up to 20 "timers" that can be used to control various  
devices, such as lights or appliances. These timers are similar in concept to  
the individual appliance timers that might be purchased at a department  
store. The devices that can be controlled are programmed into the system by  
the installer. Up to 96 of these devices can be programmed. Refer to the  
Programming Device Timers section for procedures.  
To Access another Partition (GOTO Command)  
Each keypad is assigned a default partition for display purposes, and will  
show only that partition's information. But, if the user is authorized, a  
keypad in one partition can be used to perform system functions in another  
partition, by using the GOTO command. Note that only those partitions  
authorized and programmed by the installer can be accessed in this manner.  
To GOTO another partition, enter your security code, then press [] followed  
by the desired partition number (1-8).  
The keypad will remain in the new partition until directed to go to another  
partition, or until 2 minutes has elapsed with no keypad activity. Entering  
your security code, pressing [] followed by [0] will return the keypad to its  
original partition.  
Master Keypad Operation  
A "Master" keypad is one on which the status of all eight partitions is  
displayed simultaneously. A user can get more information about a certain  
partition by simply entering [] + the desired partition number (1-8). To log  
on to the "Master" partition (9) using the GOTO command, and to perform  
any functions at a Master keypad, a user must have access to all partitions.  
8 –  
 
System Overview (contd)  
Self-Help Feature  
Abbreviated user instructions are built into the system that can be easily  
viewed on the alpha keypad's message display screen. This feature will prove  
particularly useful if this manual is not conveniently accessible when you  
need to perform a system procedure with which you are not familiar.  
To view the abbreviated instructions:  
Simply press and hold down the function key of interest until the description  
starts to appear (about 5 seconds) and then release it. The system must be  
“READY TO ARM” to perform this function.  
Refer to the Functions of the Keypad section for descriptions of each key  
function.  
9 –  
 
About The Keypads  
General  
IMPORTANT: If the keypad beeps rapidly upon entering the  
premises, it indicates that an alarm has occurred during your  
absence. LEAVE the premises IMMEDIATELY and CONTACT  
THE POLICE from a safe location nearby.  
Your keypads allow you to control all system functions. The keypads feature  
a telephone style (digital) keypad and a Liquid Crystal Display (LCD) that  
shows the nature and location of all occurrences. Keypad display back  
lighting is programmable to always stay on or to light only when a key is  
pressed, then turn off a few minutes later.  
The keypads also feature a built-in sounder that will sound during alarms  
and troubles. It will also "beep" during certain system functions, such as  
during entry/exit delay times, during CHIME mode, and when depressing  
keys to perform system functions (to acknowledge the key press). These  
sounds can be optionally suppressed in some of your keypads (so as not to  
disturb other users of the system). Ask your installer if this has been done.  
The Alpha Keypad  
Alpha keypads feature a 2-line, 32-character alphanumeric LCD that can  
display system messages in user-friendly English. Abbreviated user  
instructions can also be displayed (see Self Help paragraph in the SYSTEM  
OVERVIEW section). These keypads can also be programmed with custom  
zone descriptors.  
NOTE: There may be multiple keypads on your system. One, the primary  
keypad, will continue to operate under faulted conditions.  
10 –  
 
Functions of the Keypad  
1
4
7
2
5
8
0
3
6
9
#
Primary Fire Keypad 6160CR-2  
IMPORTANT! When using the keypad to enter codes and commands,  
sequential key depressions must be made within 3 seconds of one  
another. If 3 seconds elapse without a key depression, the entry is  
aborted and must be repeated from its beginning.  
11 –  
 
Functions of the Keypad (contd)  
ARMED  
READY  
OFF  
MAX  
AWAY  
TEST  
CODE  
STAY  
3
BYPASS  
6
CHIME  
9
#
1
4
7
2
5
8
0
INSTANT  
READY  
Burglary Keypad 6160  
IMPORTANT! When using the keypad to enter codes and commands,  
sequential key depressions must be made within 3 seconds of one  
another. If 3 seconds elapse without a key depression, the entry is  
aborted and must be repeated from its beginning.  
12 –  
 
Functions of the Keypad (contd)  
ALPHA DISPLAY WINDOW: A 2-line,  
32-character Liquid Crystal Display (LCD).  
Displays protection point identification and  
system status, messages, and user  
instructions.  
4 MAX:  
Arms in manner similar to  
AWAY mode, but eliminates the entry  
delay period, thus providing maximum  
protection.  
An  
alarm  
will  
occur  
immediately upon opening any protection  
point, including entry delay zones.  
1 OFF : Disarms the burglary portion of  
5 TEST : Tests the system and alarm  
the system, silences alarms and audible  
trouble indicators, and clears visual alarm  
trouble after the problem has been  
corrected.  
sounder if disarmed.  
6 BYPASS :  
Removes  
individual  
protection zones from being monitored by  
the system. Displays previously bypassed  
protection zones.  
2 AWAY :  
Completely arms both  
perimeter and interior burglary protection  
by sensing an intruder's movements  
through protected interior areas as well as  
guarding protected doors, windows, etc.  
Late arrivals can enter through an entry  
delay zone without causing an alarm if the  
system is disarmed before the entry delay  
time expires.  
7 INSTANT : Arms in manner similar to  
STAY mode, but turns off the entry delay  
period, offering greater security while  
inside and not expecting any late arrivals.  
An alarm will occur immediately upon  
opening any perimeter protection point,  
including entry delay zones.  
3 STAY : Arms the perimeter burglary  
8 CODE : Allows the entry of additional  
protection, guarding protected doors,  
windows and other perimeter protection  
points, and sounds an alarm if one is  
opened. Allows automatic bypassing of  
certain areas, which allows movement  
within your house without causing an  
alarm. Late arrivals can enter through an  
entry delay zone without causing an alarm  
if the system is disarmed before the entry  
user codes that can be given to other users  
of the system.  
9 CHIME :  
Turns on and off the  
CHIME mode. When on, any entry through  
a protected delay or perimeter zone while  
the system is disarmed will cause a tone to  
sound at the Keypad(s).  
delay time expires.  
See ARMING  
PERIMETER ONLY for a full explanation  
of the STAY key.  
13 –  
 
Functions of the Keypad (contd)  
LED ALARM INDICATOR: (RED) Lit  
when any Fire Alarm exists in the system.  
LED SILENCED INDICATOR: (AMBER)  
Lit when CODE + OFF is pressed.  
READY : When depressed prior to  
arming the system, the keypad will display  
all open protection zones within the  
keypad's home partition. This key is also  
used to display all zone descriptors that  
have been programmed for your system, by  
holding the key down for at least 5 seconds.  
LED SUPV INDICATOR: (AMBER) Lit  
when a supervisory condition exists in the  
system.  
LED TROUBLE INDICATOR: (AMBER)  
Lit when a trouble condition exists in the  
system.  
SPEAKER: Source of audible internal  
warning and confirmation sounds, as well  
as alarms (see "Summary of Audible  
Notifications").  
FUNCTION KEYS: These keys can be  
used for panic keys. Refer to the Panic Keys  
section for descriptions of these functions.  
# : Permits ARMING of the system  
without use of a security code ("Quick  
Arm", if programmed).  
KEYS 0-9: Used to enter your individual  
security access code(s).  
LED READY INDICATOR: (GREEN) Lit  
indicates system is ready to be armed,  
while unlit indicates system not ready.  
LED ARMED INDICATOR: (RED) Lit  
when the system has been armed (STAY,  
AWAY, INSTANT or MAXIMUM).  
LED POWER INDICATOR: (GREEN) Lit  
when AC power is applied to the system.  
14 –  
 
Entry/Exit Delays  
General Information  
Your system has installer-programmed time delays, known as exit delay and  
entry delay. Whenever you arm your system, exit delay gives you time to  
leave through the designated exit door without setting off an alarm. Exit  
delay begins immediately after entering any arming command, and applies to  
all modes of arming protection. If programmed, a slow beeping will sound  
throughout the exit delay period.  
Entry Delay gives you time to disarm the system when you reenter through  
the designated entrance door. But the system must be disarmed before the  
entry delay period ends, or an alarm will occur. The keypad will beep during  
the entry delay period, reminding you to disarm the system. You can also  
arm the system with no entry delay at all by using either INSTANT or  
MAXIMUM arming modes. These modes provide greater security while on  
the premises or while away for extended periods of time. See your installer  
for your delay times.  
15 –  
 
Security Codes and Authority Levels  
General Information  
At the time of installation, you were assigned an authority level and a  
personal four-digit security code, known only to you and yours. The security  
code must be entered when arming and disarming the system. The authority  
level defines the system functions that you can perform.  
As an additional safety feature, other users that do not have a need to know  
your code can be assigned different security codes, and each user can be given  
a different authority level. Users are identified by "user numbers", which are  
assigned when assigning a user's security code.  
All codes can be used interchangeably when performing system functions  
within the limits of each code's authority level (a system armed with one  
user's code can be disarmed by another user's code), with the exception of the  
Operator Level C code. See Authority Levels paragraph on the following page  
for details regarding authority levels.  
Duress Code  
This feature is intended for use if you are forced to disarm or arm the system  
under threat. When used, the system will act normally, but can silently  
notify the central station of your situation, if that service has been provided.  
The duress code is pre-assigned by the installer during installation (authority  
level 6).  
IMPORTANT: This code is useful only when the system is connected to a  
central station.  
Quick Arming  
Note: If "Quick Arming" was programmed by the installer, the [#] key can be  
pressed in place of the security code when arming the system. The security  
code must always be used to disarm the system, however.  
16 –  
 
Security Codes and Authority Levels (contd)  
Authority Levels  
Authority levels define the system functions a particular user can perform.  
Depending on the authority assigned to you, there are certain system  
functions you may be prohibited from performing. In summary, there are six  
authority levels, each having certain system restrictions as shown below.  
Level 1 Master:  
Can perform all system functions in assigned  
partitions, and can add, delete or change Manager  
and Operator level users. The Installer adds  
master codes.  
Level 2 Manager:  
Can perform system functions in assigned  
partitions, and can add, delete or change Operator  
level users.  
Level 3 Operator A:  
Level 4 Operator B:  
Level 5 Operator C:  
Can perform system functions in assigned  
partitions, but cannot add or delete other users.  
Same as Operator A, except Operator B cannot  
bypass zones of protection.  
Can arm the system in assigned partitions, but  
cannot disarm the system unless the system was  
armed with this code. This code is typically  
assigned to someone who has  
a
need to  
arm/disarm the system only at certain times (such  
as a baby-sitter).  
Level 6 Duress:  
Can arm and disarm the system, but also sends a  
silent panic alarm to the central station, if that  
service is connected.  
To view your authority level and system capabilities:  
1. Enter your code + [] + [].  
2. The keypad will display the partition(s) that you are authorized to  
operate, and your user number and authority level in each partition.  
17 –  
 
Security Codes and Authority Levels (contd)  
General Rules on Authority Levels and Changes  
A user may not delete or change the user code of the SAME or HIGHER  
authority than which he is assigned.  
A user may only ADD users to a LOWER authority level.  
A user may assign access codes only to those partitions to which the user  
adding the code has access. (Ex. a user with access to only partition 1  
cannot assign codes in partition 2.)  
The only way to assign a user's authority level is by using the "Add A  
User" procedure. To change a user's authority level, that user must first  
be deleted, and then added again.  
A user can only be DELETED or CHANGED from within the partition he  
is assigned.  
User numbers must be entered as 3-digit entries. Single digit user  
numbers must be preceded by a "00" (example, 003, 004, etc.). Security  
codes are entered as 4-digit numbers.  
Before assigning a security code, be sure it does not conflict with any  
DURESS code.  
NOTE: When adding, changing or deleting users, all other alpha keypads in  
that partition will display "User Edit Mode – Please Stand By", and key  
depressions (except Panic) at those keypads will be ignored. Panic key  
depressions will cause an alarm and terminate user entry.  
To Exit User Edit Mode  
You can exit any of the user edit modes described on the following pages at  
any time by doing the following:  
1. Press either or # , or don't press any key for 10 seconds.  
2. System returns to normal mode.  
18 –  
 
Security Codes and Authority Levels (contd)  
To Add a User  
IMPORTANT: Temporary users should not be shown how to use any system  
function they do not need to know (e.g. bypassing protection zones).  
CODE  
1. Enter Master or Manager code and press the  
8
key.  
2. Enter the new user's 3-digit User Number (002-250).  
3. Enter 4-digit security code for that user. The following prompts will  
appear.  
Enter 1 to add a new user code. Entering 0 will  
change the existing user's code to the code entered  
in step 3. See Changing A User's Code section.  
ADD NEW USER?  
0 = NO , 1 = YES  
Enter the authority level, 1-6, for this user within  
this partition.  
USER NUMBER = 003  
ENTER AUTH. LEVEL  
1=master  
2=manager  
5=operator C  
3=operator A  
6=duress code  
4=operator B  
Enter 1 (YES) to allow this user to perform group  
bypasses. Enter 0 (NO) this user will not be able to  
perform group bypasses.  
GROUP BYPASSING?  
0 = NO , 1 = YES  
If access schedules have been programmed, this  
prompt appears. Enter the user's access group  
number (1-8) if this user should have limited  
access to the system. Enter 0 if no access group  
should be assigned.  
ACCESS GROUP?  
ENTER 0-8  
Not Used.  
RF BUTTON ?  
0 = NO , 1 = YES  
19 –  
 
Security Codes and Authority Levels (contd)  
If you as a user have access to other partitions, the  
keypad will prompt for ability of this new user to  
access (GOTO) those partitions. Press 0 (NO) or 1  
(YES). If no, the system activates this user code and  
exits “Add a User” mode. If yes, the keypad prompts  
for the Global Arm option for this user.  
MULTI-ACCESS ?  
0 = NO , 1 = YES  
Press 1 (YES) if this user will be allowed to try to  
arm more than one partition at the same time.  
Press 0 if this user will arm only his assigned  
partition.  
GLOBAL ARM ?  
0 = NO , 1 = YES  
The keypad now prompts for the user’s access to the  
next partition (see GOTO command). Again press 0  
or 1. If yes, the system will automatically assign a  
user number for use in that partition and will  
prompt for authority level and global arm options  
for this user within the partition (see previous  
steps).  
PART.2 - SHOP?  
0 = NO , 1 = YES  
PART. 1 A0* WHSE  
USER 003 AUTH=3G.  
When all partitions have been displayed, the  
keypad will scroll through the partition(s) to which  
access has been assigned, and will display the user  
number, authority level and global arm option for  
each. The “G” after the authority level indicates  
that the global arm feature is active for this user  
in the displayed partition. The "*" indicates the  
partition from which this user can be changed or  
deleted. The "." at the end of the second line  
indicates that this user sends open/close reports.  
Open/close reporting is automatically active for  
any users added by you, if you have open/close  
reporting active.  
20 –  
 
Security Codes and Authority Levels (contd)  
To Change a User's Code  
CODE  
1. Enter Master or Manager code and press the  
8
key + user number  
to be changed.  
2. Enter the new code for that user.  
The system will recognize that the user number is  
already in use and will prompt whether or not this  
is a new user. Enter 0 to change the existing  
user's code to the code entered in step 3.  
The system will confirm that the change is allowed  
based on authorization level, and if so, will put the  
new code into effect.  
ADD NEW USER?  
0 = NO , 1 = YES  
USER 002 CHANGED  
SUCCESSFULLY  
Note that if changing one’s own code, the  
system will prompt for the new code to be re-  
entered. This prevents accidentally changing one's  
own code.  
21 –  
 
Security Codes and Authority Levels (contd)  
To Delete a User  
CODE  
1. Enter Master or Manager code and press the  
8
key + user number  
to be deleted.  
2. Enter Master or Manager code first entered.  
The system will recognize that the User number  
is already in use and will prompt to confirm that  
it should be deleted. Press 0 (NO) or 1 (YES).  
If yes, that user's code will be removed from all  
partitions to which it was assigned, and all  
authorization levels and other information about  
that user will be deleted. Note that a user can  
only be deleted from the partition in which it was  
first assigned, and can only be deleted by a user  
with a higher authority level. A User's security  
code cannot be deleted by oneself.  
OK TO DELETE  
0 = NO , 1 = YES  
USER CODE  
DELETED  
22 –  
 
Accessing Other Partitions  
To Access another Partition  
Each keypad is assigned a default partition for display purposes, and will  
show only that partition's information. But, if the user is authorized, a  
keypad in one partition can be used to perform system functions in other  
partitions by using the GOTO command. Note that only those partitions  
authorized and programmed by the installer can be accessed in this manner.  
To GOTO another partition:  
READY  
1. Enter your security code, then press  
+ partition number (0-8).  
Entering partition number 0 will return the keypad to its original  
partition.  
The keypad will remain in the new partition  
until directed to go to another partition, or  
until 2 minutes have elapsed with no keypad  
activity.  
LOG-ON TO  
PART. X COMPLETE  
AAAA  
2.  
AAAA = alpha descriptor programmed by the  
installer  
X = partition number  
Global Arming  
The Global Arming option may be assigned for use by some users. If Global  
Arming was enabled for use with your security code, a keypad prompt  
(message) shown below appears after pressing one of the arming function  
keys (STAY, INSTANT, AWAY, MAXIMUM, OFF).  
The prompt displays all the partitions. The user  
may only arm/disarm the partitions they are  
assigned access to.  
ARM P1 2 3 4 5 6 7 8  
HIT 0-8 XXX- - X- -  
To select the partition(s) that are to be armed,  
enter the desired number 1-8. An "X" will appear  
under that partition. Entering  
a
partition's  
number again will delete the “X” and that  
partition will not arm when this prompt is exited.  
Pressing 0 will turn all partitions the user is  
assigned access to on/off.  
When completed, press to exit. All the partitions  
with the “X” will then arm/disarm.  
23 –  
 
Accessing Other Partitions (contd)  
Global Arming Notes:  
When performing a Global Arm, if there are faults in any of the selected  
partitions, the system will enter a Summary Mode. Faulted zones in all  
the selected partitions will be displayed. These faults must be corrected  
or bypassed. This Summary Mode will end in approximately 2 minutes if  
no keys are pressed.  
When performing a Global Disarm, if any of the selected partitions has a  
condition that would cause the keypad to beep (e.g., alarm memory or a  
trouble condition), the system enters a Summary Mode and displays the  
condition. This Summary Mode will end in approximately 2 minutes if no  
keys are pressed.  
Master Keypad Operation  
A "Master" keypad is one that reflects the status of the entire system  
(Partitions 1-8) on its display. This is useful because it eliminates the need  
for a security officer in a building to have to "log-on" to various partitions  
from one partition's keypad to find out where an alarm has occurred.  
A description of a typical display follows:  
SYSTEM 1 2 3 4 5 6 7 8  
STATUS RRNN A TB  
The status of each partition is directly below the partition number on the  
display. Possible status indications include:  
A = Armed Away  
I = Armed Instant  
B = Bypassed/Ready = Alarm  
S = Armed Stay  
R = Ready  
M = Armed Maximum  
N = Not Ready  
T = Trouble  
F = Fire Alarm  
C = Comm Fail  
P = AC Power Failure L = Low System Battery  
To obtain more information regarding a particular partition, enter [] +  
[Partition No.] (i.e., 4). This will allow viewing only of that partition. In  
order to affect that partition, the user must log on with a code that has access  
to that partition. Also, in order for a user of any partition to log onto the  
"Master" partition (Partition 9) to view the status of all partitions, and to  
perform any functions at the Master keypad, that user must have access to  
all partitions. Otherwise, access will be denied.  
24 –  
 
Accessing Other Partitions (contd)  
The following is an example of what would be displayed for a fault condition  
on Zone 002 (Loading Dock Window) on Partition 1 (Warehouse) when  
logging on from a keypad on Partition 9:  
WHSE DISARMED  
HIT FOR FAULTS  
This is the normal display that appears at Partition 1's keypad(s). Pressing ✴  
will display:  
FAULT 002 LOADING  
DOCK WINDOW  
Additional zone faults will be displayed one at a time. To display a new  
partition's status, press + [Partition No.]. This will display the status of  
the new partition.  
The "Armed" LED on a Master keypad will be lit only if all partitions have  
been armed successfully. The "Ready" LED will be lit only if all partitions  
are "ready to arm."  
The sounder on a Master keypad will reflect the sound of the most critical  
condition on all of the partitions. The priority of the sounds is as follows:  
A. Pulsing fire alarm sounds  
B. Steady burglar alarm sounds  
C. Trouble sounds  
The sounder may be silenced by pressing any key on the Master keypad.  
25 –  
 
Accessing Other Partitions (contd)  
Common Lobby Operation  
When an installation consists of a partition that is shared by users of other  
partitions in a building, the shared partition may be assigned as a “common  
lobby” partition for the system. An example of this might be in a medical  
building where there are two doctors and a common entrance area.  
This option employs logic for automatic arming and disarming of the common  
lobby. Partitions may be set to affect and/or attempt to arm the common  
lobby. This will affect the way the lobby will react when arming or disarming  
activity occurs in another partition.  
Partitions that affect the lobby will cause the following to occur:  
a. When the first partition that affects the lobby is disarmed, the lobby will  
also be disarmed.  
b. The common lobby cannot be armed unless every partition selected to  
affect the lobby is armed.  
c. Arming the last partition that affects the lobby will not automatically  
attempt to arm the lobby.  
Partitions set to arm the lobby will cause the following to occur:  
a. Arming any partition programmed to arm the lobby will automatically  
attempt to arm the lobby. If any faults exist in the lobby partition, or  
another partition that affects the lobby is disarmed, the lobby cannot be  
armed, and the message “UNABLE TO ARM LOBBY PARTITION” will  
be displayed.  
The following chart summarizes how the common lobby partition will  
operate:  
Partition Affects  
Lobby  
Partition Arms  
Lobby  
Disarms When  
Partition Disarms  
Attempts to Arm  
When Partition  
Arms  
Can Be Armed if  
Other Partitions  
Disarmed  
NO  
YES  
YES  
NO  
NO  
NO  
NO  
YES  
YES  
NO  
NO  
YES  
NO  
YES  
YES  
YES  
NO  
---ENTRY NOT ALLOWED---  
26 –  
 
Accessing Other Partitions (contd)  
How User Codes Affect the Common Lobby  
Codes with “Global” Arming  
If your code is given “global arming” when it is defined, the system displays a  
prompt that allows you to pick and choose the partitions to be armed or  
disarmed. This eliminates the “automatic” operation of the lobby. Keep in  
mind, however, that if attempting to arm all the partitions you have access  
to, and another affecting partition is disarmed, (one you do not have access  
to) you will not be able to arm the lobby, and the message “UNABLE TO  
ARM LOBBY PARTITON” will be displayed.  
Codes with “Non-Global” Arming  
If arming with a non-global code, the lobby partition operation will be  
automatic, as described in the previous table.  
Other Methods of Arming/Disarming  
When arming or disarming a partition that affects and/or arms the common  
lobby in one of the following manners, lobby logic remains active:  
Quick-Arm  
Keyswitch  
Wireless Button  
Wireless Keypad  
27 –  
 
Checking For Open Zones  
Using the ✴  
READY Key  
Before arming your system, all protected doors, windows and other protection  
zones must be closed or bypassed (see BYPASSING section). Otherwise the  
keypad will display a "Not Ready" message. Using the READY key will  
display all zones that are faulted, making it easier for you to secure any open  
zones.  
To show faulted zones:  
NOTE: Some keypads light a green LED when  
the system is ready. If not lit, the system is not  
ready to be armed.  
DISARMED - PRESS  
TO SHOW FAULTS  
READY  
1. Do not enter security code, but simply press  
.
FAULT 005 FRONT  
UPSTAIRS BEDROOM  
Typical fault display  
Secure or bypass the zones displayed before  
arming the system. The "Ready" message will  
2.  
DISARMED  
READY TO ARM  
be displayed when all protection zones have  
been either closed or bypassed.  
NOTE: All or part of this message may be  
replaced by a customized message programmed  
by the installer. Bear this in mind whenever  
the instructions indicate that the  
"DISARMED" or "READY" message will be  
displayed.  
28 –  
 
Displaying All Zone Descriptors  
Using the READY Key  
The Alpha Keypads can also display all the zone descriptors that are  
programmed in your system. The abbreviated instructions for the READY  
key will appear first, followed by the zone descriptors. Displaying all  
descriptors is useful when you need to know the zone number of a particular  
zone, as when bypassing zones.  
The "Disarmed-Ready to arm" message must be displayed before zone  
descriptors can be displayed.  
READY  
Press the  
key and hold down for at least 5 seconds.  
29 –  
 
Bypassing Protection Zones  
Using the 6 BYPASS Key  
This key is used when you want to arm your system with one or more zones  
intentionally unprotected. Bypassed zones are unprotected and will not cause  
an alarm when violated while your system is armed. All bypasses are  
removed when an OFF sequence (security code plus OFF) is performed.  
Bypasses are also removed if the arming procedure that follows the bypass  
command is not successful.  
NOTE: The system will not allow fire or emergency zones to be  
bypassed.  
To bypass zones, the system must be disarmed first.  
BYPASS  
1. Enter your security code and press  
6
.
2. Enter zone number(s) for the zones to be bypassed (e.g., 001, 002, 003,  
etc.).  
IMPORTANT! All single-digit numbers must be preceded by “00” (for  
example, enter 001 for zone 1).  
3. Press [] + [].  
4.  
When finished, the keypad will display the  
word BYPASS along with each bypassed zone  
number. Wait for these zones to be displayed  
before arming. Arming the system before  
bypassed zones are displayed eliminates all  
bypasses.  
BYPASS 007 FRONT  
UPSTAIRS BEDROOM  
Typical bypass message  
5.  
Arm the system as usual when the keypad  
displays "ready" to arm message.  
DISARMED BYPASS  
READY TO ARM  
30 –  
 
Bypassing Protection Zones (contd)  
Quick Bypass  
Your system allows you to easily bypass all open (faulted) zones without  
having to enter zone numbers individually.  
Note: All bypasses are removed when an OFF sequence (security code plus  
OFF) is performed.  
To use the Quick Bypass feature:  
BYPASS  
1. Enter your security code and press  
6
then press # .  
In a few moments, all open zones will be  
displayed along with the word BYPASS. Wait  
for these zones to be displayed before arming.  
Arming the system before bypassed zones are  
displayed eliminates all bypasses.  
BYPASS 007 FRONT  
UPSTAIRS BEDROOM  
Typical bypass message  
2.  
3.  
Arm the system as usual when the keypad  
displays the "ready" to arm message. Bypassed  
zones are unprotected and will not cause an  
alarm when violated while your system is  
armed.  
DISARMED BYPASS  
READY TO ARM  
Displaying Bypassed Zones  
For determining what zones have been previously bypassed. Bypassed zones  
can be displayed only when system is disarmed.  
BYPASS  
1. Enter your security code and press  
6
.
2. Wait for all bypassed zones to be sequentially displayed.  
31 –  
 
Bypassing Protection Zones (contd)  
Group Bypass  
Your system allows you to easily bypass a group of zones without having to  
enter zone numbers individually. The system provides up to 15 groups. There  
is no limit to the number of zones that may be assigned to any one group.  
Check with your installer for a list of zones assigned to the group(s).  
NOTES:  
All bypasses are removed when an OFF sequence (security code plus OFF) is  
performed.  
Users must be assigned the following attributes to perform the group bypass  
function:  
Enabled for group bypassing  
Access to the partition(s) containing the zones being bypassed  
Global arming capability.  
To use the Group Bypass feature:  
BYPASS  
1. Enter your security code and press  
group number (01-15).  
6
then press  
then enter the  
In a few moments, all the zones in the group  
will be displayed along with the word BYPASS.  
Wait for these zones to be displayed before  
arming. Arming the system before bypassed  
zones are displayed eliminates all bypasses.  
BYPASS 007 FRONT  
UPSTAIRS BEDROOM  
Typical bypass message  
2.  
Arm the system as usual when the keypad  
displays the "ready" to arm message. Bypassed  
zones are unprotected and will not cause an  
alarm when violated while your system is  
armed.  
DISARMED BYPASS  
READY TO ARM  
3.  
32 –  
 
Arming Perimeter Only  
(With Entry Delay ON)  
Using the 3 STAY key  
Use this key when you are staying home, but might expect someone to use  
the entrance door later.  
When armed in STAY mode, the system will sound an alarm if a protected  
door or window is opened, but you may otherwise move freely throughout the  
premises. Late arrivals can enter through the entrance door without causing  
an alarm, but they must disarm the system within the entry delay period or  
an alarm will occur.  
The system provides three STAY modes. STAY mode 1, 2, and 3. When  
activated, STAY modes 1 and 2 automatically bypass specific zones assigned  
by your installer to each of the STAY modes. STAY mode 3, when activated,  
automatically bypasses all zones assigned to STAY modes 1 AND 2. Check  
with your installer for a list of the zones that are bypassed during each STAY  
mode.  
Close all perimeter windows and doors before arming (see  
CHECKING FOR OPEN ZONES section)  
STAY  
1. Enter your security code and press  
Enter your security code and press  
Enter your security code and press  
3
3
3
+
+
+
1 for STAY Mode 1.  
2 for STAY Mode 2.  
3 for STAY Mode 3.  
NOTE: If none of the zones in a partition are assigned to Stay mode 2, then  
when the user enters [User Code] + [3] (STAY), all zones assigned to Stay  
mode 1 are automatically bypassed.  
The keypad beeps three times, displays the  
armed message, and indicates which STAY  
mode (1, 2 or 3).  
ARMED ***STAY 1*  
ZONE BYPASSED  
2.  
NOTE: "ZONE BYPASSED" in this display  
simply indicates that some zones of protection  
are not armed when using STAY mode.  
33 –  
 
Arming Perimeter Only  
(With Entry Delay ON) (contd)  
Auto-STAY Arming  
Auto-stay allows the system to automatically bypass certain zones if upon  
arming none of the entry/exit zones are faulted during the exit delay time (no  
one exits the premises). The system provides an option to set each burglary  
zone for Auto-stay. All zones enabled for auto-stay except for perimeter and  
day/night types of zones, has exit delay time when the partition is armed.  
Check with your installer for the zones assigned for Auto-STAY.  
NOTES:  
Auto-STAY applies to all four arming modes (AWAY, STAY, INSTANT  
and MAXIMUM).  
Arming the partition AWAY via an RF transmitter overrides the Auto-  
stay feature (partition will not bypass zones programmed for auto-stay).  
34 –  
 
Arming Perimeter Only  
(With Entry Delay OFF)  
Using the 7 INSTANT Key  
Use this key when you are staying home and do not expect anyone to use the  
entrance door.  
When armed in INSTANT mode, the system will sound an alarm if a  
protected door or window is opened, but you may otherwise move freely  
throughout the premises. The alarm will also sound immediately if anyone  
opens the entrance door.  
The system provides three INSTANT modes: INSTANT mode 1, 2, and 3.  
INSTANT modes 1 and 2, when activated, automatically bypass specific  
zones assigned by your installer to each of the INSTANT modes. INSTANT  
mode 3, when activated, automatically bypasses all zones assigned to  
INSTANT modes 1 and 2. Check with your installer for a list of the zones  
that are bypassed during each INSTANT mode.  
Close all perimeter windows and doors before arming (see  
CHECKING FOR OPEN ZONES section)  
INSTANT  
1. Enter your security code and press  
Enter your security code and press  
Enter your security code and press  
7
7
7
+
+
+
1 for INSTANT Code 1.  
2 for IINSTANT Mode 2.  
3 for INSTANT Mode 3.  
NOTE: If none of the zones in a partition are assigned to INSTANT mode 2,  
then when the user enters [User Code] + [7] (INSTANT), all zones assigned  
to INSTANT mode 1 are automatically bypassed.  
The keypad beeps three times, displays the  
armed message and indicates which INSTANT  
mode (1, 2, or 3).  
ARMED *INSTANT1  
ZONE BYPASSED  
2.  
NOTE: "ZONE BYPASSED" in this display  
simply indicates that some zones of protection  
are not armed when using RSTART mode.  
35 –  
 
Arming All Protection  
(With Entry Delay ON)  
Using the 2 AWAY Key  
Use this key when no one will be staying on the premises.  
When armed in AWAY mode, the system will sound an alarm if a protected  
door or window is opened, or if any movement is detected inside the premises.  
You may leave through the entrance door during the exit delay period  
without causing an alarm. You may also reenter through the entrance door,  
but must disarm the system within the entry delay period or an alarm will  
occur.  
Close all perimeter windows and doors before arming (see  
CHECKING FOR OPEN ZONES section)  
AWAY  
1. Enter your security code and press  
2
.
ARMED **AWAY**  
YOU MAY EXIT NOW  
The keypad will beep twice and will display the  
armed message.  
2.  
NOTE: The "YOU MAY EXIT NOW" portion of  
the message disappears when exit delay  
expires.  
36 –  
 
Arming all Protection  
(with Entry Delay OFF)  
Using the 4 MAXIMUM Key  
Use this key when the premises will be vacant for extended periods of time  
such as vacations, etc., or when no one will be moving through protected  
interior areas.  
When armed in MAXIMUM mode, the system will sound an alarm if a  
protected door or window is opened, or if any movement is detected inside the  
premises. You may leave through the entrance door during the exit delay  
period without causing an alarm, but an alarm will be sounded as soon as  
someone reenters.  
Close all perimeter windows and doors before arming (see Checking  
for Open Zones section).  
MAXIMUM  
1. Enter your security code and press  
4
.
The keypad will beep twice and will display the  
armed message.  
ARMED *MAXIMUM*  
YOU MAY EXIT NOW  
2.  
NOTE: The "YOU MAY EXIT NOW" portion of  
the message disappears when exit delay  
expires.  
37 –  
 
Quick Exit  
Using the # + 9 Keys  
The Quick Exit feature allows you to exit the armed partition without having  
to disarm and then rearm the partition.  
To Quick Exit the premises:  
1. Press the # key and then press the 9 key.  
2. The system will sound the exit beeps, if enabled, and will give you the  
programmed exit delay time to leave the premises.  
38 –  
 
Disarming and Silencing Alarms  
Using the 1 OFF Key  
The OFF key is used to disarm the system and to silence alarm and trouble  
sounds. See Summary of Audible Notification section for information that  
will help you to distinguish between FIRE and BURGLARY alarm sounds.  
IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter  
the premises, but call the police from a nearby safe location. If you return after an  
alarm has occurred and the main sounder has shut itself off, the keypad will beep  
rapidly upon entering, indicating that an alarm has occurred during your absence.  
LEAVE the premises IMMEDIATELY and CONTACT THE POLICE from a  
nearby safe location.  
To disarm the system and silence burglary or fire alarms:  
OFF  
1. Enter your security code and press  
1
.
DISARMED  
READY TO ARM  
2. The Ready message will be displayed (if no alarms have occurred while  
armed) and the keypad will beep once to confirm that the system is  
disarmed.  
Memory of Alarm  
The keypad displays the zone number and type of alarm for any zone that  
has an alarm condition. These messages will remain displayed until cleared  
by a user. If an alarm has occurred, note the zone number displayed on the  
keypad and repeat step 1 above to clear the "Memory of Alarm" and restore  
the Ready message display. If the Ready message will not display, go to the  
displayed zone and remedy the fault (close windows, etc.). If the fault cannot  
be remedied, notify the alarm agency.  
If the system was armed when the alarm occurred, repeat step 1 twice: once  
to disarm the system, a second time to clear the display.  
39 –  
 
Using the Keyswitch  
General  
Your system may be equipped with a keyswitch for use when arming and  
disarming a partition. A red and green light on the keyswitch plate indicate  
the status of your system as follows:  
Green Light: Lights when the system is disarmed and ready to be  
armed (no open zones). If the system is disarmed and the  
green light is off, it indicates the system is not ready (one or  
more zones are open).  
Red Light: Lights when system is armed or memory of alarm exists.  
Lit Steady: Partition is armed in AWAY mode.  
Slow Flashing: Partition is armed in STAY mode.  
Rapid Flashing: Memory of alarm, indicating an alarm has occurred.  
Arming  
To arm in the AWAY mode, turn the key to the right for 1 second and  
release. Keypads will beep twice and the  
red light will stay on steady.  
To arm in the STAY mode, turn the  
key to the right and hold for longer than  
10 seconds, then release. Keypads will  
beep three times and the red light will  
GREEN  
RED  
flash slowly.  
Disarming  
To disarm the partition, turn the key  
to the right and release. If an alarm has  
occurred, the red light will be flashing  
rapidly (memory of alarm).  
keyswitch-001-V1  
NOTE: Your system may be  
programmed to use the keyswitch to  
silence fire alarms without affecting the  
status of the burglary portion of the  
system. Check with your installer to see  
if this feature has been enabled.  
40 –  
 
Chime Mode  
Using the 9 Key  
Your system can be set to alert you to the opening of a door or window while  
it is disarmed by using CHIME mode. When activated, three tones will sound  
at the Keypad whenever a protected perimeter door or window is opened, and  
the Not Ready message will be displayed. Pressing the READY key will  
display the open protection points.  
Note that Chime mode can be activated only when the system is disarmed.  
1. To turn Chime Mode on, enter the security code and press 9 .  
The CHIME MODE ON message will appear  
CHIME MODE ON  
for about 2 seconds then disappear. To display  
this message again (to determine whether  
chime mode is on or off), simply press and hold  
down the CHIME key for 5 seconds.  
2. To turn Chime Mode off, enter the security code and press  
9
again.  
The CHIME MODE OFF message will appear  
for about 2 seconds then disappears. To display  
this message again (to determine whether  
chime mode is on or off), simply press and hold  
down the CHIME key for 5 seconds.  
CHIME MODE OFF  
41 –  
 
Viewing Alarm Company Messages  
General Information  
Users of the system may periodically receive messages on their display  
screens from their monitoring agency or installer. When a message is waiting  
to be viewed, the message shown below will appear.  
MESSAGE. PRESS 0  
FOR 5 SECS.  
1. Press and hold down 0 key for 5 seconds.  
2. The message could take up to four screens to display all the information  
available.  
NOTE: Any message sent by the central station downloader may be viewed  
at any partition’s keypad.  
42 –  
 
Panic Keys  
(For Manually Activating Silent and/or Audible Alarms)  
Using Panic Keys  
Your system may have been programmed to use special key combinations to  
manually activate panic functions. The functions that might be programmed  
are Silent Emergency, Audible Emergency, and Personal Emergency. See  
your installer for the function(s) that may have been programmed for your  
system.  
Active Panic Functions  
(Your installer should note which  
function(s) is active in your  
system.)  
To use a paired key panic function,  
simply press both keys of the assigned  
pair at the same time.  
Keys  
1 and *  
3 and #  
* and #  
A
Zone Function  
995  
996  
999  
995  
999  
996  
If your keypad(s) have lettered keys for  
panic functions, press the designated  
key and hold down for at least 2 seconds  
to  
activate  
the  
panic  
function.  
B
C
A silent emergency sends a silent alarm signal to the central station, but  
there will be no audible alarms or visual displays.  
An audible emergency sends an emergency message to the central station  
(if connected) and will sound a loud, steady alarm at your keypad and at any  
external sounders that may be connected (ALARM plus a zone number  
would also be displayed).  
A personal emergency alarm sends an emergency message to the central  
station (if connected) and will sound at Keypads, but not at external  
Notification Appliance Circuits. (ALARM plus a zone number would also be  
displayed.)  
43 –  
 
Relay Control  
General Information  
Your system may be set up using a relay so that a door (such as in a lobby)  
can be unlocked momentarily using a keypad command. Ask your installer if  
this has been done in our system.  
Executing  
To activate the relay enter your security code + [0] at the keypad. The door  
will unlock for 2 seconds.  
44 –  
 
Using #70 Relay Menu Mode  
General Information  
Your system may be set up so that certain lights or other devices can be  
turned on or off by using the #70 command from a keypad. Ask your installer  
if this has been done in your system.  
To activate relays from a keypad, enter 4-digit security code + [#] +70.  
Follow the keypad prompts described below.  
NOTE: Your installer may have restricted the use of this function. Please  
check with your installer.  
Enter the 2-digit number of the device to be  
activated.  
ENTER DEVICE NO.  
00=QUIT  
01  
Note that if an invalid number is entered, the  
system will simply ask you to reenter the number.  
Press 0 or 1 to turn the device off or on respectively.  
"nn" represents the 2-digit device number and voice  
descriptor is the relay voice descriptor programmed  
by the installer.  
NN DEVICE IS OFF  
HIT 0=OFF , 1=ON  
From a keypad, press to continue. The ENTER  
NN DEVICE IS OFF  
DEVICE NO. prompt will appear.  
HIT THE "" KEY  
45 –  
 
Using Schedules  
Delaying the Closing Time  
Your system's programmed schedules may automatically arm the system at a  
predetermined time. In the event a user must stay on the premises later than  
usual, users with master or manager authority levels can manually delay the  
automatic arming (closing) time up to 2 hours. To delay the closing time:  
1. Enter your security code (master or manager authority levels only).  
2. Press the # key, followed by 82.  
3. A menu prompt will be displayed, asking for the number of hours of delay.  
Enter the desired number of hours of delay, 1 or 2.  
The system automatically exits this mode after  
entry.  
CLOSING DELAY?  
KEY 0-2 HOURS  
Note that the delay is from the scheduled closing time, not from the  
time the command is entered.  
IMPORTANT: The selected delay cannot be reduced once it is set. A 1-  
hour delay can be increased to 2 hours, though.  
4. The system will automatically send a message to the central station  
informing them that the programmed schedule has been changed.  
Temporary Open/Close Schedules  
Temporary schedules allow you to override the normal schedules  
programmed by the installer. Temporary schedules can be in effect for up to  
one week, and take effect as soon as they are programmed.  
They are comprised of an arming (closing) time window and a disarming  
(opening) time window. A time window is simply a defined period of time, at  
the end of which arming or disarming will occur.  
Before programming, use a worksheet similar to the one below to plan your  
schedule. This will make it easier when actually programming the schedule.  
Arm/Disarm  
Mon  
Tue  
Wed  
Thu  
Fri  
Sat  
Sun  
Windows  
Disarm Window  
Start Time HH:MM  
Stop Time HH:MM  
Arm Window  
Start Time HH:MM  
Stop Time HH:MM  
46 –  
 
Using Schedules (contd)  
Programming Temporary Schedules  
Temporary schedules only affect the partition from which it is entered.  
Temporary schedules can be reused at later dates simply by scrolling (by  
pressing #) to the DAYS? prompt (described below) and activating the  
appropriate days. This should be considered when defining daily time  
windows. Note that only users with authority level of manager or higher can  
program temporary schedules.  
To program temporary schedules:  
1. Enter your security code.  
2. Press the # key followed by 81.  
3. The following prompts will appear.  
The cursor will be positioned on the tens of hours  
digit of the start time for Monday's disarm  
MON DISARM WIND.  
07:45AM 08:45AM  
window. Enter the desired hour. Press * to move  
to the minutes field. The minutes are entered in  
the same manner. The AM/PM indication is  
changed by hitting any key, 0-9, while the cursor  
is under the letter A/P position. Repeat for the  
stop time entry. Press the * key to move to the  
arming window for Monday.  
Press # to move to the next screen display  
without making changes.  
The cursor will be positioned on the tens of hours  
digit of the start time for the arm window. Repeat  
the previous steps to enter the start and stop  
time for Monday's arming window.  
MON ARM WINDOW  
07:45AM 08:45AM  
After the windows for that day have been  
completed, the system will prompt for disarm and  
arm time windows for the next day. Repeat the  
procedure for all days of the week.  
TUE DISARM WIND.  
07:45AM 08:45AM  
When all of the days have been completed, the  
system will ask which days are to be activated.  
47 –  
 
Using Schedules (contd)  
This is the prompt that actually activates the  
DAYS ? MTWTFSS  
HIT 0-7 X X  
temporary schedule, and allows the temporary  
schedule to be customized to a particular week's  
needs. To select the days that are to be activated,  
enter the desired number 1-7 (Monday = 1). An  
"X" will appear under that day, indicating the  
previously entered schedule for that day is active.  
Entering a day's number again will deactivate  
that day. Pressing 0 will turn all days on/off.  
The temporary schedule will only be in effect for  
the days which have the letter x underneath  
them. As the week progresses, the days are reset  
to the inactive state.  
When completed, press * to exit the temporary  
schedule entry mode.  
48 –  
 
Programming Device Timers  
General Information  
Device timers consist of an ON time and an OFF time, and selected days of  
the week in which they are active. There are up to 20 timers that can be used  
to control various devices, such as lights or appliances. Your installer will  
have programmed the appropriate devices into the system (up to 96 devices  
can be programmed).  
Each timer controls a single device (designated as an output number) that  
you select. For example, timer 1 might be set to turn the porch lights on at  
7:00pm and turn them off at 11:00pm. Timer 2 might turn on the air  
conditioner Monday-Friday at 4:30pm to cool the premises before you arrive  
at 5:00pm, and turn it off at 10:00pm when you are retiring for the night. If  
desired, different timers can control the same device. For example, timer 2  
could be used Monday-Friday as in the previous example, and timer 3 could  
be set to turn the air conditioner on and off at different times Saturday and  
Sunday.  
To enter the device timer menu mode:  
Enter your security code, then press the  
#
key followed by 83.  
Up to 20 timers can be programmed. A number 1-  
20 identifies each timer. Enter the desired timer  
number to be programmed (1-20). Press * to  
accept entry.  
OUTPUT TIMER # ?  
01-20,00=QUIT 01  
If that timer number has already been  
programmed, a summary screen will appear. In  
this example:  
06 07:00P 11:45P  
PORCH LITE 04  
06 = Timer #  
04 = Output Device # affected by this timer  
PORCH LITE = Output Descriptor for Device 4  
07:00PM = Start Time;  
11:45PM = Stop Time  
Press * to continue.  
See your installer for  
device numbers.  
Enter the desired output device number (1-96).  
As the number is entered, the device's description  
will appear.  
00 ENTER OUTPUT#  
00  
To delete a previously programmed timer, enter  
00 as the output number.  
49 –  
 
Programming Device Timers (contd)  
Enter the time you want the device turned on  
00 ON TIME ?  
00:00 PM  
using 00:01 - 11:59 format. When the display  
shows the desired time, press the * key to move  
to the AM/PM field. Press any key 0-9 to change  
the AM/PM indication.  
Enter 00:00 if this timer is not being used to turn  
something ON for the days selected below. (Ex.  
using one timer to turn lights on one day and  
using another timer to turn them off on another  
day).  
Enter the time you want the device turned off  
using 00:01 - 11:59 format. When the display  
shows the desired time, press the * key to move  
to the AM/PM field. Press any key 0-9 to change  
the AM/PM indication.  
00 OFF TIME ?  
00:00 PM  
Enter 00:00 if this timer is not being used to turn  
something OFF for the days selected below. (Ex.  
using one timer to turn lights on one day and  
using another timer to turn them off on another  
day).  
Select the days on which the device is to be  
activated by entering 1-7 (Monday = 1). An "X"  
will appear under that day, indicating the output  
for that day is active. Entering a day's number  
again will deactivate that day. Pressing 0 will  
turn all days on/off. The outputs will only be in  
effect for the days that have the letter x  
underneath them. As the week progresses, the  
days are reset to the inactive state, unless the  
permanent option is selected (next screen  
prompt). When completed, press * to continue.  
00 DAYS? MTWTFSS  
HIT 0-7  
X X  
Answering 1 (YES) means the system executes  
this timer continuously. Answering 0 (NO) means  
the system executes each day's output only once.  
00 PERMANENT ?  
0 = NO, 1 = YES  
0
50 –  
 
Programming Device Timers (contd)  
Randomize Output Device Times  
Devices in your system may be set for a random schedule, whereby they will  
turn on and off at different times each day. This is useful when going on  
vacation and you desire the turning on and off of the lights to the give the  
appearance of someone being home. Your installer sets these devices for a  
random schedule. You can initiate a random schedule by either of the  
following methods:  
1. Enter your security code and press # followed by 41.  
This will randomize, up to 30 minutes, the activation time of all devices,  
programmed for randomization, assigned to the partition the sequence is  
entered in. Enter the sequence again to turn off the random schedule.  
2. Enter your security code and press # followed by 42.  
This is the same as the method above, except the randomization occurs  
only on devices with activation times within 6 PM and 5 AM. Enter the  
same sequence again to turn off the random schedule.  
51 –  
 
Using #77 Instant Activation Mode  
The #77 Instant Activation Mode is used to activate outputs, bypass zones,  
etc. immediately upon exiting the #77 Mode. The actions that may be  
activated are relay commands, arm/disarm commands, zone bypassing  
commands, and open/close access conditions.  
Relay Commands  
Action Code  
Action Specifier  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
Relay On  
Relay Off  
Relay Close for 2 seconds  
Relay Close XX minutes ✳  
Relay Close YY seconds ✳  
Relay Group On  
Relay #  
Relay #  
Relay #  
Relay #  
Relay #  
Relay Group #  
Relay Group #  
Relay Group #  
Relay Group #  
Relay Group #  
Relay Group Off  
Relay Group Close for 2 seconds  
Relay Group Close XX minutes ✳  
Relay Group Close YY seconds ✳  
Check with your installer for the amount of time.  
Arm/Disarm Commands  
Activation times 1 (Beginning), 2 (End), and 3 (During) are the only valid  
choices for automatic arming and disarming functions.  
"During" can be used to arm or disarm the control for a specific time only.  
For example, if "during" is selected with Arm-STAY, the system will  
automatically Arm-STAY at the beginning of the window and automatically  
disarm at the end of the window.  
Action Code  
Action Specifier  
20  
21  
22  
23  
24  
25  
26  
Arm-STAY  
Arm AWAY  
Disarm  
Force Arm STAY (Auto-bypass faulted zns)  
Force Arm AWAY (Auto-bypass faulted zns)  
Arm INSTANT  
Partition(s)  
Partition(s)  
Partition(s)  
Partition(s)  
Partition(s)  
Partition(s)  
Partition(s)  
Arm MAXIMUM  
52 –  
 
Using #77 Instant Activation Mode (contd)  
Bypass Commands  
Activation times 1 (Beginning), 2 (End), and 3 (During) are the only valid  
choices for bypass commands. If 3 (During) is selected for auto-bypassing,  
the system bypasses the zone(s) specified on a particular zone list at the  
beginning of the window and unbypasses them at the end of the window. If it  
is selected for auto unbypassing, the system removes the bypass at the  
beginning of the window and restores the bypass at the end of the window.  
Action Code  
Action Specifier  
30  
31  
Auto bypass - Zone list  
Auto unbypass - Zone list  
Zone list #  
Zone list #  
Open/Close Windows  
Activation time 3 (During) is the only valid choice for these commands.  
Action Code  
Action Specifier  
40  
41  
42  
Enable Opening Window by partition  
Enable Closing Window by partition  
Enable Access Window for access group  
Partition(s)  
Partition(s)  
Access Group  
Access Control Commands  
Action Code  
Action Specifier  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
66  
67  
68  
69  
70  
71  
72  
73  
74  
Access Point Grant  
Access Point Grant with Override  
Access Point Protect  
Access Point Bypass  
Access Point Lock  
Access Point #  
Access Point #  
Access Point #  
Access Point #  
Access Point #  
Access Point #  
Group #  
Group #  
Group #  
Group #  
Group #  
Partition #  
Partition #  
Partition #  
Partition #  
Partition #  
Partition #  
Trigger #  
Access Point Exit  
Access Point Group Grant  
Access Point Group Grant with Override  
Access Point Group Protect  
Access Point Group Bypass  
Access Point Group Exit  
Access Point Partition Grant  
Access Point Partition Grant with Override  
Access Point Protect by Partition  
Access Point Bypass by Partition  
Access Point Lock by Partition  
Access Point Exit by Partition  
Access Point Trigger On  
Access Point Trigger Off  
Trigger #  
53 –  
 
Using #77 Instant Activation Mode (contd)  
Additional Commands  
Action Code  
Action Specifier  
77  
78  
Access Point Group Enable  
Access Point Group Disable  
Group #  
Group #  
To enter the Instant Activation Mode:  
Enter your security code; then press the [#] key followed by 77.  
Enter the code for the desired action. The  
action codes are the events that are to take place  
when either the system exits the #77 Mode or the  
scheduled time is reached, depending on the action  
selected.  
ACTION ?  
Press [] to continue.  
Enter the action specifier. This defines what the  
action will affect (relay, relay group, partition, zone  
list, user group). The action specifier screen prompt  
varies, depending on the type of action selected.  
As an example, if you selected “Auto Bypass” as the  
action, the action specifier prompt would be:  
ZONE LIST?  
Enter 1 (YES) or 0 (NO).  
Press [] to continue.  
ARE YOU SURE?  
1 = YES 0 = NO  
0
Enter 1 (YES) or 0 (NO).  
Press [] to continue.  
QUIT MENU MODE?  
1 = YES 0 = NO  
54 –  
 
Event Log Procedures  
General Information  
To Display The Event Log  
The system has the ability to record  
various events in a history log wherein  
each event is recorded in one of five  
categories (listed below), with the time and  
date of its occurrence. The Event Log holds  
up to 1000 events, with the oldest event  
being replaced by the logging of any new  
event after the log is full. Using an alpha  
keypad, the Event Log can be viewed one  
category at a time, or can display all  
events, regardless of category (ALL  
EVENT LOG). The system also allows  
selection of displaying the COMPLETE log,  
or only those events occurring since the  
last installer service (RECENT). In  
addition, events in the other partitions can  
be viewed by users authorized to access  
those partitions. Note that events are  
displayed in chronological order, from most  
recent to oldest.  
1. Enter CODE + [#] + [6] + [0]  
2. Select the display mode.  
RECENT: Displays only those events  
occurring since last Event Log Clear  
command was executed.  
COMPLETE: Displays complete event  
log (up to 1000 events).  
Press the desired key, 0 or 1.  
ENTER 0 = RECENT  
1 = COMPLETE  
3. Select the partition, 0-8.  
Enter the partition number for the  
partition whose events are to be  
displayed.  
Entering  
0
(NO) will display all  
partitions' events.  
SCAN LOG BY PART  
0=NO 1-8=PART #  
55 –  
 
Event Logging Procedures (continued)  
4. Use the [3] and [1] keys (for next and  
previous categories respectively) to  
display the categories of events.  
ALARM EVENT LOG  
Displays time and date for zones which  
have either caused an alarm or have been  
restored in the selected partition.  
Press [8] to select a category and  
display the first event. Press [8] again  
for each subsequent event.  
Shows burglary alarm occurred in zone  
3 (C03) of partition 1 (P1), at 12:02AM  
on January 1.  
CHECK EVENT LOG  
Displays time and date for zones which  
have caused a trouble or supervisory  
condition in the selected partition.  
BYPASS EVENT LOG  
Displays time and date for zones which  
have been bypassed in the partition.  
P1 01/01 12:02AM  
BURGLARY C003  
Typical  
Event Log  
Display  
OPEN EVENT LOG  
Displays time, date and user number or 6-  
character descriptor for the user, if  
programmed, for each arming and  
disarming of the system for the partition  
selected.  
After the last event has been  
displayed, the END OF EVENT LOG  
message appears for a few seconds,  
then the system automatically displays  
the RECENT/COMPLETE mode select  
screen again (see step 2).  
SYSTEM EVENT LOG  
Displays time and date for system  
problems, such as AC Loss, low battery,  
etc., regardless of partition.  
5. To EXIT the Event Log:  
Press [] at any time.  
ALARM EVENT LOG Typical  
ALL EVENT LOG  
Displays all categories of events in  
chronological order.  
TYPE  
CCC UUU Category  
Select Screen  
See your Installer for  
additional information  
concerning the event log.  
56 –  
 
Testing the System (To Be Conducted Weekly)  
Using the 5 TEST Key  
The TEST key puts your system into Burglary Walk Test mode, which allows each  
burglary protection point to be checked for proper operation.  
1. Disarm the system and close all protected windows, doors, etc. READY should be  
displayed.  
TEST  
2. Enter your security code and press the  
5
key.  
3. The external sounder should sound for 3 seconds and then turn off. If the sounder  
does not sound, it may be due to dialer communication activity. Wait a few minutes  
and try again. If the sounder still does not sound, CALL FOR SERVICE  
IMMEDIATELY.  
4. The keypad will sound a single beep every 15 seconds as a reminder that the system  
is in Test mode. Each time a protection zone is faulted (opened); the keypad should  
beep three times. If the sounder does not sound, CALL FOR SERVICE  
IMMEDIATELY.  
NOTES:  
No alarm reports will be sent to the central monitoring station while the system  
is in Test mode.  
The system will automatically exit the Test mode if there is no activity (no doors or  
windows are opened and closed, no motion detectors are activated, etc.) for 60 minutes.  
The system will beep the keypad(s) twice every 5 seconds during the last 5 minutes as a  
warning that it is about to exit the Test mode and return to normal operation.  
Testing Your System  
1. Open and close each protected door and window in turn and listen for three beeps.  
Each faulted protection point should appear on the display.  
2. Walk in front of any motion detectors (if used) and listen for three beeps as  
movement is detected (wireless motion detectors have a 3-1/2 minute lockout  
between trips). Each detector’s should appear on the display when it is activated.  
3. Follow the manufacturer's instructions to test all smoke detectors to ensure that all  
are functioning properly. Each detector should appear on the display when activated.  
4. When all protection points have been checked, there should be no zone identification  
numbers displayed. If a problem is experienced with any protection point (no  
confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY.  
5. Turn off Test mode by entering the security code + the OFF key.  
57 –  
 
Fire Alarm System  
Your fire alarm system (if installed) is on 24 hours a day, providing  
continuous protection. In the event of an emergency, the smoke and heat  
detectors automatically send signals to your Control, triggering a loud  
interrupting sound from the keypad and the optional exterior sounders.  
FIRE appears at your keypad and remains on until you silence the alarm.  
In Case Of Fire Alarm  
1. Should you become aware of a fire emergency before your detectors sense  
the problem, go to your nearest keypad and manually initiate an alarm  
by pressing the panic key assigned as FIRE emergency (if programmed  
by the installer) and hold down for at least 2 seconds.  
2. Evacuate all occupants from the premises.  
3. If flames and/or smoke are present, leave the premises and notify your  
local Fire Department immediately.  
4. If no flames or smoke are apparent, investigate the cause of the alarm.  
The descriptor of the zone(s) in alarm appears at the keypad.  
Silencing a Fire Alarm  
1. Silence the keypad by entering your code and pressing the OFF key.  
This may or may not also silence the fire bells. A second entry may be  
required, depending on system programming. To clear the display, enter  
your code and press the OFF key again  
2. If the keypad does not indicate a READY condition after the second OFF  
sequence, press the READY key to display the zone(s) that are faulted.  
Be sure to check that smoke detectors are not responding to smoke or  
heat producing objects in their vicinity. Should this be the case,  
eliminate the source of heat or smoke.  
3. If this does not remedy the problem, there may still be smoke in the  
detector. Clear it by fanning the detector for about 30 seconds.  
4. You can clear the display by entering your code + the OFF key.  
58 –  
 
Fire Alarm System (contd)  
Event Display Lock  
If several zones produce an alarm, trouble or supervisory, the system will  
display the first zone that produced an event. To display the other zone(s) in  
alarm or trouble, press the [*] key for each zone.  
Fire Drill Test (Code + # + 69)  
This test causes Notification Appliance Circuits to be activated for the  
purpose of conducting a fire drill or a bell test. This can only be activated by  
the installer or a master user from Partition 1 keypads as follows:  
1. Enter the corresponding security code and press [#} + 69 (make sure the  
burglary portion of the system is disarmed). Keypads will display “FIRE  
DRILL ACTIVE” while the test is active.  
2. The test may be stopped by entering any security code and pressing OFF.  
NOTE: The system continues to monitor all 24-hour zones (fire, panic, etc.),  
while this test is active, and will end the test when an alarm condition is  
detected. This test should be conducted at periodic intervals as determined  
by the local authority having jurisdiction.  
59 –  
 
Trouble Conditions  
Typical Trouble Displays  
The word CHECK or TRBL on the Keypad's display, accompanied by a rapid  
"beeping" at the Keypad, indicates there is a trouble condition in the system.  
To silence the beeping sound for trouble conditions, press any key.  
“CHECK” or “TRBL” display accompanied by a display of "CALL  
SERVICE" indicates that a problem exists with the system that  
eliminates some of the protection. CALL FOR SERVICE  
IMMEDIATELY.  
“CHECK” or “TRBL" display accompanied by a display of one or more  
zone descriptors indicate that a problem exists with those zone(s). First,  
determine if the zone(s) displayed are intact (this may include Fire and  
Waterflow type zones) and make them so if they are not. If the problem  
has been corrected, key an OFF sequence (Code plus OFF) to clear the  
“CHECK” or “TRBL” display. If the display persists, CALL FOR  
SERVICE IMMEDIATELY.  
“CHECK” or “TRBL” display accompanied by a display of “6XX,” where  
XX = 01-32, indicates a trouble on a supervised relay (corresponding  
relay number 01-32).  
“CHECK” or “TRBL” display accompanied by a display of “8XX,” where  
XX = 00-30, indicates a trouble on a peripheral device (connected to the  
panel’s keypad terminals).  
“CHECK” or “TRBL” display accompanied by a display of “9XX,” where  
XX = 00-99, indicates a system trouble exists (dialers, Notification  
Appliance Circuits, ground fault, etc.). These zones are as follows:  
970: Bell 1 Output  
971: Bell 2 Output  
975: Dialer 2  
988: 2nd RF Receiver – not receiving signals  
972: Earth Ground Fault 990: 1st RF Receiver – not receiving signals  
973: J2 Trigger Output  
974: Dialer 1  
997: Polling Loop Short  
SUPV” display accompanied by a display of one or more zone  
descriptors indicates a problem on fire supervisory zone(s). This means  
that the operation of the fire alarm system may be compromised. First,  
determine if the zone(s) displayed are intact and make them so if they  
are not. If the problem has been corrected, key an OFF sequence (Code  
plus OFF) to clear the “SUPV” display. If the display persists, CALL  
FOR SERVICE IMMEDIATELY.  
60 –  
 
Trouble Conditions (contd)  
A display of "COMM. FAILURE" at the Keypad indicates that a failure  
has occurred in the telephone communication portion of your system.  
CALL FOR SERVICE IMMEDIATELY.  
A display of "SYSTEM LO BAT", accompanied by a once per minute  
"beeping" at the Keypad indicates that a low system battery condition  
exists. CALL FOR SERVICE IMMEDIATELY.  
A display of "LO BAT" and a zone descriptor, accompanied by a once per  
minute "beeping" at the Keypad indicates that a low battery condition  
exists in the wireless transmitter displayed. CALL FOR SERVICE  
IMMEDIATELY.  
A display of "MODEM COMM" indicates that the control is on-line with  
the central station's remote computer. The control will not operate while  
on-line.  
A display of “HSENS” and a zone number indicates a smoke detector  
with a high sensitivity level, which may cause false alarms. CALL FOR  
SERVICE IMMEDIATELY.  
A display of “LSENS” and a zone number indicates a smoke detector  
with a low sensitivity level. Detectors with a low sensitivity might not  
detect a smoke condition. CALL FOR SERVICE IMMEDIATELY.  
Power Failure  
If the message "AC LOSS" is displayed, the Keypad is operating on battery  
power only. If only some lights are out on the premises, check circuit  
breakers and fuses and reset or replace as necessary. CALL FOR SERVICE  
IMMEDIATELY if AC power cannot be restored.  
SERVICING INFORMATION  
Your local HONEYWELL dealer is the person best qualified to service your  
alarm system. Arranging some kind of regular service program with him is  
advisable. Your local HONEYWELL dealer is:  
Name:  
Address:  
Phone:  
61 –  
 
Emergency Evacuation  
Establish and regularly practice a plan of escape in the event of fire. The following steps are  
recommended by the National Fire Protection Association:  
1. Position your detector or your interior and/or exterior sounders so that  
they can be heard by all occupants.  
2. Determine two means of escape from each room. One path of escape  
should lead to the door that permits normal exit from the building. The  
other may be a window, should your path be impassable. Station an  
escape ladder at such windows if there is a long drop to the ground.  
3. Sketch a floor plan of the building. Show windows, doors, stairs and  
rooftops that can be used to escape. Indicate escape routes for each room.  
Keep these routes free from obstruction and post copies of the escape  
routes in every room.  
4. Assure that all fire doors are shut while you in the building. This will  
prevent deadly smoke from entering while you escape.  
5. Try the door. If the door is hot, check your alternate escape route. If the  
door is cool, open it cautiously. Be prepared to slam the door if smoke or  
heat rushes in.  
6. Where smoke is present, crawl on the ground; do not walk upright.  
Smoke rises and may overcome you. Clearer air is near the floor.  
7. Escape quickly; don't panic.  
8. Establish a common meeting place outdoors, away from your house,  
where everyone can meet and then take steps to contact the authorities  
and account for those missing. Choose someone to assure that nobody  
returns to the house — many die going back.  
62 –  
 
Maintaining Your System  
Taking Care of Your System  
The components of your security system are designed to be as free of  
maintenance as possible. However, there are some things you can do to make  
sure that your system is in reliable working condition.  
1. Test your system weekly. (See TESTING THE SYSTEM and FIRE  
ALARM SYSTEM sections).  
2. Test the system after any alarm occurs.  
Replacing Batteries in Wireless Sensors  
Wireless sensors  
may not have  
been used in your  
security system  
Each wireless sensor in your system has a 9-volt or 3-volt battery. The system  
detects a low battery in any wireless sensor, including smoke detectors, the  
optional personal emergency transmitter, and the optional portable wireless  
keypad. (A low battery in a portable wireless keypad is detected as soon as  
one of its keys is pressed, and the keypad will display 00.)  
Alkaline batteries provide a minimum of 1 year of operation, and in most  
units and applications, provide 2–4 years of service. Actual battery life will  
depend on the environment in which the sensor is used, the number of signals  
that the transmitter in the sensor has had to send, and the specific type of  
sensor. Factors such as humidity, high or low temperatures or large swings  
in temperature, may all lead to the reduction of actual battery life in an  
installation.  
If you have a low battery in a wireless sensor, a low battery message  
is displayed on the keypad.  
In addition, a battery-operated smoke detector with a low battery also emits  
a single "chirp" sound once approximately every 20-30 seconds, identifying  
itself as the smoke detector with the weak battery. If you do not replace a  
smoke detector's low battery, the smoke detector may sound continuously, as  
if there were a fire alarm.  
NOTE: The low battery message comes on as a warning that battery  
replacement in indicated sensor(s) is due within 30 days. In the meantime,  
the sensor(s) causing the low battery indication is still fully operational.  
IMPORTANT: Use only batteries recommended by your installer as  
replacement.  
63 –  
 
Maintaining Your System (contd)  
Silencing Low Battery Warning Tones at the Keypad  
The keypad’s warning tones can be silenced by performing an OFF sequence  
(code plus OFF key), but the Keypad's low battery message display will  
remain on as a reminder that you have a low battery condition in one or more  
of your sensors. When you replace the weak battery with a fresh one, the  
sensor will send a "good battery" signal to the control as soon as the sensor is  
activated (opening/closing of door, window, etc.), causing the low battery  
display to turn off. If the sensor is not activated, the display will  
automatically clear within approximately 1 hour.  
Routine Care  
Treat the components of your security system as you would any other  
electrical equipment. Do not slam sensor-protected doors or windows.  
Keep dust from accumulating on the keypad and all protective sensors,  
particularly on motion sensors and smoke detectors.  
The keypad and sensors should be cleaned carefully with a dry soft cloth.  
Do not spray water or any other fluid on the units.  
NOTE: It is important that your system is tested periodically to  
insure proper protection. This includes testing the fire alarm  
portion of your system. See TESTING THE SYSTEM and FIRE  
ALARM SYSTEM sections for the testing procedures.  
64 –  
 
Quick Guide to Fire System Functions  
ACTION  
PROCEDURE  
Displaying Event  
The system is programmed to lock the keypad display with the first event that  
occurred in priority order.  
1. Fire – highest priority  
2. Life Safety  
3. Troubles and Supervisory  
4. System Events (i.e. low battery) – lowest priority  
To display the next event, press the [*] key. Repeat as necessary.  
To revert to the first event displayed, press the # key.  
Silencing Fire Alarms  
Resetting Alarms  
Enter User Code +1 (OFF). This will silence the keypad, but may or may not  
silence the fire bells, depending on system programming. A second User Code  
+ 1 (OFF) sequence may be required. The Silenced LED on the 6160CR-2  
keypad will light.  
To reset alarms, enter User Code + 1 (OFF) a second time. This will clear  
alarms from memory.  
Silencing Troubles and  
Supervisory Conditions  
To Silence Troubles or Supervisory Conditions, enter User Code +1 (OFF). The  
corresponding LED on the 6160CR-2 keypad will light.  
Resetting Troubles and  
Supervisory Conditions  
Troubles and supervisory conditions automatically reset when the condition is  
cleared if programmed by your installer. Otherwise reset the condition by  
entering Code + 1 (OFF).  
65 –  
 
Quick Guide to Burglary System Functions  
FUNCTION  
Check Zones  
Display All  
PROCEDURE  
Press [].  
Press and hold [] for 5 seconds.  
COMMENTS  
To view faulted zones when is system not ready  
Displays all alpha descriptors programmed by  
installer.  
Descriptors  
Arm System  
Enter code.  
Press arming key desired (AWAY,  
STAY, INSTANT, MAXIMUM).  
Arms system in mode selected.  
NOTE: After pressing the STAY or INSTANT  
arming key, enter 1, 2 or 3 to arm in  
the desired STAY or INSTANT mode.  
Disarms system and silences alarms.  
Bypassed zones are unprotected and will not  
cause an alarm if violated.  
Disarm System  
Bypass Zones  
Enter code. Press OFF [1].  
Enter code. Press BYPASS [6].  
Enter zone numbers to be  
bypassed (use 3-digit entries).  
Press [] + [].  
Quick Bypass  
Group Bypass  
Enter code. Press BYPASS [6].  
Press [#].  
Enter code. Press BYPASS [6].  
Press []. Enter Group Number  
(01-15)  
Bypasses all faulted zones automatically.  
Bypasses all zones assigned to the group.  
Chime Mode  
Test Mode  
Enter code. Press CHIME [9].  
Keypad will sound if doors or windows are  
violated while system disarmed.  
Activates alarm sounder and allows sensors to  
be tested.  
Enter code. Press TEST [5]  
View Messages  
Press and hold [0] for at least 5  
seconds.  
Message from central station will appear.  
View User  
Capabilities  
Enter user's code. Press [] + [].  
Displays partitions and authority levels  
assigned to the user.  
GOTO Partition  
Enter security code. Press [].  
Enter partition number (1-8).  
0 returns to default partition.  
Allows a user at one keypad to perform  
functions in another partition, if that user is  
authorized to do so.  
Self-Help  
Press and hold any function key for Will display abbreviated instructions for the key  
at least 5 seconds.  
pressed.  
Add a User  
Enter master/manager code.  
Press CODE [8].  
Enter new user's user number.  
Enter code for that user.  
Enter authority for that user in this  
partition (1-5).  
Master and Manager level users can add users  
to the system, each with its own code and  
authority level.  
Follow prompts, 1=Yes, 0=No.  
Enter master/manager code.  
Press CODE [8].  
Change a User's  
Code  
Master and Manager level users can change  
their own or other users' codes.  
Enter user's 3-digit number.  
Enter new code for that user.  
Press 0 (No) at prompt.  
66 –  
 
Quick Guide to Burglary System Functions  
(contd)  
FUNCTION  
PROCEDURE  
COMMENTS  
Delete a User  
Enter master/manager code.  
Press CODE [8].  
Master and Manager level users can delete  
users.  
Enter user no. to be deleted.  
Enter master/manager code.  
Press 1 (Yes) at prompt.  
Enter security code. Press [#]  
Enter 71 or 72.  
A user can only be deleted by a user with  
higher authority level.  
Control Output  
Device  
Activate output device as programmed.  
Activate output device manually  
Enter security code. Press [#]  
Enter 70.  
Enter security code. Press [#]  
Enter 77.  
Activate output device or system event instantly  
Randomize Output Enter security code. Press [#]  
Randomize output devices set for random  
schedules  
Device  
Enter 41  
Enter security code. Press [#]  
Enter 42.  
Randomize output devices set for random  
schedules with activation times between 6 PM  
and 5 AM  
Enter the sequence used to  
activate randomization.  
De-activate randomization  
67 –  
 
Summary of Audible Notification  
(Alpha Display Keypads)  
SOUND  
LOUD,  
CAUSE  
FIRE ALARM  
DISPLAY  
FIRE is displayed; descriptor of zone in alarm is  
INTERRUPTED*  
Keypad & External  
LOUD,  
CONTINUOUS*  
Keypad & External  
ONE SHORT BEEP  
(not repeated)  
displayed.  
BURGLARY/AUDIBLE EMERGENCY  
ALARM  
ALARM is displayed; descriptor of zone in alarm is  
also displayed.  
a. SYSTEM DISARM  
a. DISARMED/READY TO ARM is displayed.  
b. The number and descriptor of the open protection  
zone is displayed.  
c. Numbers and descriptors of the bypassed  
protection zones are displayed (One beep is heard  
for each zone displayed). Subsequently, the  
following is displayed: DISARMED BYPASS Ready  
to Arm  
b. SYSTEM ARMING ATTEMPT  
WITH AN OPEN ZONE.  
c. BYPASS VERIFY  
Keypad only  
ONE SHORT BEEP  
(once every 15  
sec.) Keypad only  
TWO SHORT BEEPS  
(once every 5 sec.)  
Keypad only  
SYSTEM IS IN TEST MODE  
Opened Zone identifications will appear.  
SYSTEM IS ABOUT TO  
AUTOMATICALLY EXIT TEST  
MODE  
Opened Zone identifications will appear.  
ONE BEEP  
(every 60 sec.)  
LOW BATTERY AT A TRANSMITTER  
LO BAT displayed with description of transmitter.  
Keypad only  
TWO SHORT BEEPS  
Keypad only  
ARM AWAY OR MAXIMUM  
ARMED AWAY or ARMED MAXIMUM is displayed.  
Red ARMED indicator is lit.  
THREE SHORT  
BEEPS  
Keypad only  
a. ARM STAY OR INSTANT  
b. ZONE OPENED WHILE SYSTEM  
IS IN CHIME MODE.  
a. ARMED STAY ZONE BYPASSED or ARMED  
INSTANT ZONE BYPASSED is displayed. Red  
ARMED indicator is lit.  
b. CHIME displayed, descriptor of open protection  
zone will be displayed if the [] key is pressed.  
c. DISARM SYSTEM OR ALARM WILL OCCUR is  
displayed.  
c. ENTRY WARNING**  
RAPID BEEPING  
Keypad only  
a. TROUBLE  
b. AC POWER LOSS ALERT***  
c. MEMORY OF ALARM  
a. CHECK displayed. Descriptor of troubled  
protection zone is displayed.  
b. AC LOSS displayed (may alternate with other  
displays that may be present).  
c. FIRE or ALARM is displayed; descriptor of zone in  
alarm is displayed.  
SLOW BEEPING  
Keypad only  
a. ENTRY DELAY WARNING**  
b. EXIT DELAY WARNING  
(if programmed)  
a. DISARM SYSTEM OR ALARM WILL OCCUR is  
displayed. Exceeding the delay time without  
disarming causes alarm.  
b. ARMED AWAY or ARMED MAXIMUM is displayed  
along with You May Exit Now  
*
If bell is used as Notification Appliance, fire alarm is pulsed ring; burglary/audible emergency is steady ring.  
** Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.  
*** Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).  
68 –  
 
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS  
The user shall not make any changes or modifications to the equipment unless authorized by the Installation  
Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to  
operate the equipment.  
FCC CLASS B STATEMENT  
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC  
requires the following statement for your information:  
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in  
strict accordance with the manufacturer's instructions, may cause interference to radio and television  
reception. It has been type tested and found to comply with the limits for a Class B computing device in  
accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable  
protection against such interference in a residential installation. However, there is no guarantee that  
interference will not occur in a particular installation. If this equipment does cause interference to radio or  
television reception, which can be determined by turning the equipment off and on, the user is encouraged  
to try to correct the interference by one or more of the following measures:  
• If using an indoor antenna, have a quality outdoor antenna installed.  
• Reorient the receiving antenna until interference is reduced or eliminated.  
• Move the radio or television receiver away from the receiver/control.  
• Move the antenna leads away from any wire runs to the receiver/control.  
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different  
branch circuits.  
• Consult the dealer or an experienced radio/TV technician for help.  
INDUSTRY CANADA CLASS B STATEMENT  
ICES-003 Class B Notice - Avis NMB-003, Classe B  
This Class B digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  
FCC/IC STATEMENT  
This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the  
following two conditions: (1) This device may not cause harmful interference (2) This device must accept  
any interference received, including interference that may cause undesired operation.  
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son  
fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences  
nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris les interferences causant une  
reception indésirable.  
IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS  
In the event of telephone operational problems, disconnect the control by removing the plug from the RJ31X  
(CA38A in Canada) telephone wall jack. We recommend that your certified installer demonstrate  
disconnecting the phones on installation of the system. Do not disconnect the phone connection inside the  
control/communicator. Doing so will result in the loss of your phone lines. If the regular phone works  
correctly after the control/communicator has been disconnected from the phone lines, the  
control/communicator has a problem and should be returned for repair. If upon disconnection of the  
control/communicator, there is still a problem on the line, notify the telephone company that they have a  
problem and request prompt repair service. The user may not under any circumstances (in or out of  
warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized  
service agency for all repairs.  
69 –  
 
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE  
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a  
label that contains, among other information, the FCC registration number and ringer equivalence  
number (REN) for this equipment. If requested, this information must be provided to the  
telephone company.  
This equipment uses the following jacks:  
An RJ31X is used to connect this equipment to the telephone network.  
The REN is used to determine the quantity of devices which may be connected to the telephone  
line. Excessive RENs on the telephone line may result in the devices not ringing in response to  
an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To  
be certain of the number of devices that may be connected to the line, as determined by the total  
RENs, contact the telephone company to determine the maximum REN for the calling area.  
If this equipment causes harm to the telephone network, the telephone company will notify you in  
advance that temporary discontinuance of service may be required. If advance notice is not  
practical, the telephone company will notify the customer as soon as possible. Also, you will be  
advised of your right to file a complaint with the FCC if you believe necessary.  
The telephone company may make changes in its facilities, equipment, operations, or procedures  
that could affect the operation of the equipment. If this happens, the telephone company will  
provide advance notice in order for you to make the necessary modifications in order to maintain  
uninterrupted service.  
If trouble is experienced with this equipment, please contact the manufacturer for repair and  
warranty information. If the trouble is causing harm to the telephone network, the telephone  
company may request you remove the equipment from the network until the problem is resolved.  
There are no user serviceable components in this product, and all necessary repairs must be  
made by the manufacturer. Other repair methods may invalidate the FCC registration on this  
product.  
This equipment cannot be used on telephone company-provided coin service. Connection to  
Party Line Service is subject to state tariffs.  
This equipment is hearing-aid compatible.  
When programming or making test calls to an emergency number, briefly explain to the  
dispatcher the reason for the call. Perform such activities in the off-peak hours; such as early  
morning or late evening.  
70 –  
 
CANADIAN DEPARTMENT OF COMMUNICATIONS  
(DOC) STATEMENT  
NOTICE  
AVIS  
The Canadian Department of Communications label L’étiquette du ministère des Communications du Canada  
identifies certified equipment. This certification means identifie le matériel homologué. Cette étiquette certifie que  
that the equipment meets certain telecommunications le matériel est conforme à certaines normes de protection,  
network  
requirements. The Department does not guarantee the télécommunications. Le ministère n’assure toutefois pas  
equipment will operate to the user’s satisfaction. que le matériel fonctionnera à la satisfaction de l’utilisateur.  
protective,  
operational  
and  
safety d’exploitation  
et  
de  
sécurité  
des  
réseaux  
de  
Before installing this equipment, users should ensure Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il  
that it is permissible to be connected to the facilities of est permis de le raccorder aux installations de l’entreprise  
the local telecommunications company. The equipment locale de télécommunications. Le matériel doit également  
must also be installed using an acceptable method of être installé en suivant une méthode acceptée de  
connection. In some cases, the company’s inside wiring raccordement. Dans certains cas, les fils intérieurs de  
associated with a single line individual service may be l’entreprise utilisés pour un service individuel à la ligne  
extended by means of certified connector assembly unique peuvent être prolongés au moyen d’un dispositif  
(telephone extension cord). The customer should be homologué de raccordement (cordon prolongateur  
aware that compliance with the above conditions may téléphonique interne). L’abonné ne doit pas oublier qu’il est  
not prevent degradation of service in some situations.  
possible que la conformité aux conditions énoncées ci-  
dessus n’empèchet pas la dégradation du service dans  
certaines situations. Actuellement, les entreprises de  
télécommunications ne permettent pas que l’on raccorde  
leur matériel aux prises d’abonnés, sauf dans les cas precis  
prévus par les tarifs particuliers de ces entreprises.  
Les réparations du matériel homologué doivent être  
effectuées pas un centre d’entretien canadien autorisé  
désigné par le fournisseur. La compagnie de  
Repairs to certified equipment should be made by an  
authorized Canadian maintenance facility designated  
by the supplier. Any repairs or alterations made by the  
user to this equipment, or equipment malfunctions, may  
give the telecommunications company cause to request  
the user to disconnect the equipment.  
Users should ensure for their own protection that the  
electrical ground connections of the power utility,  
telephone lines and internal metallic water pipe system,  
if present, are connected together. This precaution may  
be particularly important in rural areas.  
Caution: User should not attempt to make such  
connections themselves, but should contact the  
appropriate electric inspection authority, or electrician,  
as appropriate.  
The Load Number (LN) assigned to each terminal  
device denotes the percentage of the total load to be  
connected to a telephone loop which is used by the  
device, to prevent overloading. The termination on a  
loop may consist of any combination of devices subject  
only to the requirement that the total of the Load  
Numbers of all the devices does not exceed 100.  
télécommunications peut demander  
à
l’utilisateur de  
débrancher un appareil à la suite de réparations ou de  
modifications effectuées par l’utilisateur ou à cause de  
mauvais fonctionnement.  
Pour sa propre protection, l’utilisateur doit s’assurer que  
tous les fils de mise en terre de la source d’énergie  
électrique, des lignes téléphoniques de réseau de conduites  
d’eau s’il  
y
en a, soient raccordés ensemble. Cette  
précaution est particulièrement importante dans les régions  
rurales.  
Avertissement: L’utilisateur ne doit pas tenter de faire ces  
raccordements lui-même; il doit avoir recours à un service  
d’inspection des installations électriques, ou à un électricien,  
selon le cas.  
L’indice de charge (IC) assigné à chaque dispositif terminal  
pour éviter toute surcharge indique le pourcentage de la  
charge totale qui peut être raccordé  
à
un circuit  
téléphonique bouclé utilisé par ce dispositif. La terminaison  
du circuit bouclé peut être constituée de n’importe quelle  
combinaison de dispositifs, pourvu que la somme des  
indices de charge de l’ensemble des dispositifs ne dépasse  
pas 100.  
71 –  
 
WARNING!  
THE LIMITATIONS OF THIS ALARM SYSTEM  
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or  
other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a  
variety of reasons. For example:  
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor  
or disconnect an alarm warning device.  
Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work  
without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put  
in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.  
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if  
the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the  
path.  
A user may not be able to reach a panic or emergency button quickly enough.  
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not  
activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the  
Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System  
may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may  
not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other  
side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second  
floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors have sensing  
limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about  
fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage  
of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending upon the nature  
of the fire and/or the locations of the smoke detectors, the detector, even if it operates as anticipated, may not provide  
sufficient warning to allow all occupants to escape in time to prevent injury or death.  
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation  
manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of  
protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion  
or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows.  
Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical  
system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the  
ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection performance can  
decrease.  
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the  
other side of closed or partly open doors. If warning devices sound on a different level of the residence from the  
bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not  
hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic.  
Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers.  
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or  
temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.  
Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect  
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond  
appropriately.  
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to  
last as long as 10 years, the electronic components could fail at any time.  
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance.  
This alarm system should be tested weekly to make sure all sensors and transmitters are working properly.  
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for  
insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and  
continue to insure their lives and property.  
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved  
ones to learn about these developments.  
72 –  
 
Index  
#70 command.........................................45  
AC Loss..................................................61  
Access Another Partition ....................23  
Access Control Commands....................53  
Action Code ..........................................52  
Action Specifier....................................52  
Add a User ............................................19  
ADD NEW USER ...................................21  
Add User Code.......................................18  
Ademco Dealer.......................................61  
Alarm ........................................................7  
Alkaline batteries....................................63  
Alpha Keypads .......................................10  
Arm/Disarm Commands.........................52  
Armed...................................................6, 7  
ARMED INDICATOR .............................14  
Audible Emergency ................................43  
Audible Signals.......................................68  
Authority Level........................................16  
Authority Levels................................17, 18  
Auto-STAY Arming.................................34  
Away...................................................6, 23  
AWAY.....................................................40  
AWAY mode...........................................36  
battery life...............................................63  
Burglary....................................................5  
Burglary Protection...............................6, 7  
Bypass Commands ................................53  
Bypass Zones.........................................30  
Bypassing .............................................30  
Call Service ............................................60  
Change a User's Code .........................21  
Change User Code.................................18  
CHECK...................................................60  
Chime .................................................6, 41  
Closing Time ..........................................46  
Comm. Failure........................................61  
Common Lobby......................................26  
Delaying Closing Time.........................46  
Delete a User.........................................22  
Delete User Code .................................. 18  
Descriptors............................................. 29  
Device Timers .................................. 8, 49  
Disarm ................................................... 39  
DOC....................................................... 71  
Duress ................................................... 17  
Duress Code......................................... 16  
Emergency............................................... 5  
Entry Delay ............................................ 15  
Entry/Exit ................................................. 6  
Event Display Lock ................................ 59  
Event Log Procedures ........................... 55  
Exit Delay............................................... 15  
Exit User Edit Mode............................. 18  
Fire..................................................... 5, 43  
fire alarm................................................ 58  
Fire Drill Active....................................... 59  
Fire Drill Test ......................................... 59  
Fire Protection ......................................... 6  
GLOBAL ARM ....................................... 20  
Global Arming........................................ 23  
Goto ....................................................... 20  
GOTO .................................................... 23  
GOTO Command..................................... 8  
Group Bypass........................................ 32  
HSENS .................................................. 61  
Instant ................................................ 6, 23  
INSTANT ............................................... 15  
INSTANT mode ..................................... 35  
Keypad..................................................... 5  
Keypad back lighting.............................. 10  
Keypads................................................. 10  
Keyswitch............................................... 40  
LO Bat.................................................... 61  
Low Battery............................................ 63  
Low Battery Warning........................... 64  
LSENS................................................... 61  
Manager................................................. 17  
Master.................................................... 17  
Master Keypad................................... 8, 24  
73 –  
 
Maximum............................................6, 23  
MAXIMUM..............................................15  
MAXIMUM mode....................................37  
Memory of Alarm..............................7, 39  
Messages...............................................42  
Modem Comm........................................61  
MULTI-ACCESS ....................................20  
Not Ready ..............................................28  
Off...........................................................23  
OFF........................................................39  
Open Zones ..........................................28  
Open/Close Schedules ........................46  
Open/Close Windows.............................53  
Operator A..............................................17  
Operator B..............................................17  
Operator C .............................................17  
OUTPUT TIMER ....................................49  
Panic Keys............................................43  
PANIC KEYS .........................................14  
Partitioned Security System.....................5  
Partitioned System...................................5  
Personal Emergency..............................43  
POWER/READY INDICATOR...............14  
Quick Arm ..............................................14  
Quick Arming........................................16  
Quick Bypass .......................................31  
Quick Exit...............................................38  
Quick Guide ...............................65, 66, 67  
Randomize Output Devices ...................51  
Ready ....................................................28  
READY...................................................41  
Ready Key..............................................28  
Relay commands ...................................52  
Relay Menu Mode.................................45  
Replacing Batteries..............................63  
RF BUTTON...........................................19  
Routine Care .........................................64  
Schedules...........................................7, 46  
Security Code.........................................16  
Security Codes .......................................16  
Sensing Devices.......................................6  
Silencing A Fire Alarm............................58  
Silent Emergency ...................................43  
Smoke Detectors....................................57  
Stay ....................................................6, 23  
STAY ......................................................40  
STAY mode ............................................33  
System LO Bat .......................................61  
System Overview......................................5  
Temporary Schedules ......................46, 47  
Temporary Users....................................19  
Test Key .................................................57  
Test mode...............................................57  
Testing Your System ..............................57  
Time Window..........................................46  
TRBL......................................................60  
Trouble Condition ...................................60  
UNABLE TO ARM LOBBY.....................26  
User Edit Mode.......................................18  
User Numbers ........................................16  
User's Instructions....................................9  
Using #77 Instant Activation Mode.........52  
Wireless Sensor .....................................63  
Zone Bypassed.......................................33  
Zone Descriptors ....................................29  
Zones.......................................................6  
74 –  
 
TWO YEAR LIMITED WARRANTY  
Honeywell International Inc., acting through its Security & Communications business (“Seller”), 2 Corporate Center Drive,  
Melville, New York 11747 warrants its products to be free from defects in materials and workmanship under normal use  
and service, normal wear and tear excepted, for 24 months from the manufacture date code; provided, however, that in  
the event the Buyer presents a proper invoice relating to the purchased product and such invoice bears a date later than  
the manufacture date, then Seller may at its discretion, reflect the warranty period as commencing at invoice date. Except  
as required by law, this Limited Warranty is only made to Buyer and may not be transferred to any third party. During the  
applicable warranty period, Seller will repair or replace, at its sole option and as the exclusive remedy hereunder, free of  
charge, any defective products.  
Seller shall have no obligation under this Limited Warranty or otherwise if the product:  
(i)  
(ii)  
is improperly installed, applied or maintained;  
installed outside of stated operating parameters, altered or improperly serviced or repaired by anyone other  
than the Seller/Seller’s Authorized Service/Repair Center;  
(iii)  
(iv)  
damage is caused by outside natural occurrences, such as lightning, power surges, fire, floods, acts of  
nature, or the like; or  
defects result from unauthorized modification, misuse, vandalism, alterations of serial numbers, other causes  
unrelated to defective materials or workmanship, or failures related to batteries of any type used in  
connection with the products sold hereunder.  
Exceptions to Warranty With Respect to Honeywell Products listed below:  
Hardwire Contacts and PIRs – Seller warrants parts for hardwire contacts and PIRs in accordance with the terms of the  
above limited warranty for a period of five (5) years from the manufacture date code.  
EXCLUSION OF WARRANTIES, LIMITATION OF LIABILITY  
THERE ARE NO WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS  
FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE  
HEREOF. TO THE FULLEST EXTENT PERMITTED BY LAW, IN NO CASE SHALL SELLER BE LIABLE TO ANYONE  
FOR ANY (i) CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES ARISING OUT OF OR  
RELATING IN ANY WAY TO THE PRODUCT AND/OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR  
CONDITION, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE  
LOSS OR DAMAGE IS CAUSED BY SELLER’S OWN NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN  
ADVISED OF THE POSSIBILITY OF SUCH LOSSES OR DAMAGES. Any product description (whether in writing or  
made orally by Seller or Seller’s agents), specifications, samples, models, bulletin, drawings, diagrams, engineering  
sheets or similar materials used in connection with the Buyer’s order are for the sole purpose of identifying the Seller’s  
products and shall not be construed as an express warranty or condition. Any suggestions by Seller or Seller’s agents  
regarding use, applications, or suitability of the products shall not be construed as an express warranty or condition  
unless confirmed to be such in writing by Seller. Seller does not represent that the products it sells may not be  
compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire  
or otherwise, or that the products will in all cases provide adequate warning or protection. Buyer understands that a  
properly installed and maintained alarm may only reduce the risk of a burglary, robbery or fire without warning, but it is not  
insurance or a guarantee that such will not occur or will not cause or lead to personal injury or property loss.  
CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR  
OTHER LOSS BASED ON ANY CLAIM AT ALL INCLUDING A CLAIM THE PRODUCT FAILED TO GIVE WARNING.  
However, if Seller is held liable whether directly or indirectly for any loss or damage with respect to the products it sells,  
regardless of cause or origin, its maximum liability shall not in any case exceed the purchase price of the product, which  
shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the  
Seller. Should your product become defective during the warranty, please contact your installer to facilitate repair or  
replacement with Seller pursuant to the terms hereof. Seller reserves the right to replace any defective product under  
warranty with new, refurbished, or remanufactured product.  
 
NOTES  
 
NOTES  
 
NOTES  
 
NOTES  
 
2 Corporate Center Drive, Suite 100  
P.O. Box 9040, Melville, NY 11747  
Copyright © 2009 Honeywell International Inc.  
ÊK0377V2eŠ  
K0377V2 7/09 Rev. B  
 

Grandstream Networks Telephone Accessories 486 User Manual
Haier Water Heater FCD 8 User Manual
Hamilton Beach Iron 840154800 User Manual
HANNspree Flat Panel Television LT0B 15A1 User Manual
Honeywell Door RPWL201A User Manual
Hotpoint Washer Dryer AQ7F User Manual
HP Hewlett Packard Laptop XE2 User Manual
HP Hewlett Packard Switch OS 3 User Manual
IBM Switch 12122EA6 User Manual
Impex Elliptical Trainer NS 652 User Manual