Hunter Fan Humidifier 31004 User Manual

Ultrasonic  
Humidifier  
Owners Manual  
Model  
31004  
Form# 44061-01  
20100802  
©2010 Hunter Fan Co.  
 
At A Glance  
1
Warnings and Know Your Humidifier  
ReAd And SAve tHeSe inStRUctiOnS!  
important Safety instructions: Read all instructions before  
using this humidifier.  
• This humidifier may not work properly on an uneven surface. ALWAYS place this  
humidifier on a firm, level, and water resistant surface.  
• ALWAYS place the humidifier at least six (6) inches away from walls, heat sources, and  
electrical appliances such as stoves, radiators, or heaters.  
• ALWAYS place the humidifier in an area that is out of the reach of children.  
• Before using the humidifier, extend the cord and inspect for any signs of damage. dO  
nOt use the product if the cord has been damaged.  
• This product has a polarized plug (one blade is wider than the other) as a safety feature.  
This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the  
outlet, reverse the plug. If it still does not fit, contact a qualified electrician. dO nOt  
attempt to defeat or override this safety feature.  
• ALWAYS UnPLUG And eMPtY the humidifier when it is not in operation or while it  
is being cleaned.  
• Use only clean, cool tap water when filling the tank. dO nOt use hot water.  
• Never add medication of any type to the water tank.  
You should never leave the unit unattended in a closed room. The room can become  
saturated and leave condensation on walls and furniture. Always leave a door partially  
open.  
• This device complies with part 18 of the FCC Rules.  
Thank you for purchasing the Ultrasonic Humidifier by Hunter Fan Company. Please read and  
save these instructions to receive the maximum benefit and performance from your humidifier.  
Mist Exhaust  
Tank Handle  
Water  
Tank  
Refill Tank Light  
Humidifier Base  
Humidity Adjustment  
3
©2010 Hunter Fan Company  
 
Using Your Humidifier  
2
Initial Setup and Operation  
Tank Handle  
initial Setup:  
1. Remove the plastic bag covering from the humidifier.  
2. Unravel and straighten the cord before use.  
3. Remove the tank from the humidifier base by grasping the  
4. Turn the tank upside down and twist the tank cap counter-  
5. Fill the unit with clean, cool tap water.  
Warning: Never fill the humidifier with hot water.  
Figure 1  
6. Place the tank cap back on the tank and turn it clockwise  
until secure.  
7. Seat the tank back into the humidifier base, making sure  
the tank is seated securely.  
nOte: Failure to ensure the tank is seated correctly could  
cause the unit to leak water from the tank.  
8. Plug the humidifier into a wall outlet and start the unit.  
ON/OFF  
Water Level  
Operation:  
1. To turn the humidifier on, turn the humidity adjustment knob  
clockwise until you feel the knob click. At this time the unit  
should be on and you can adjust the amount of mist the  
unit outputs by continuing to turn the knob clockwise. To  
turn the unit off, turn the humidity adjustment knob counter-  
Figure 2  
Tank Cap  
2. When the unit is out of water, the water level light will  
3. Refilling the water tank and placing it securely back on the  
base will turn this feature off. Figure 4.  
Figure 3  
ON/OFF  
Water Level  
Figure 4  
4
44061-01 • 08/02/2010  
 
         
Maintenance  
3
Cleaning and Storage  
note: ALWAYS unplug the humidifier from the electrical  
outlet before cleaning. neveR allow water to sit in the tank  
when not in use.  
daily Maintenance:  
1. Turn off the humidifier and unplug it from the wall outlet.  
2. Remove the tank unit by pulling it straight off the humidifier  
base.  
3. Turn the tank upside down and drain any water into a sink  
or tub. Shake the unit gently to remove any remaining water.  
4. Rinse the tank thoroughly with water, empty, and wipe with  
a dry, clean cloth.  
5. Wipe the humidifier base with a dry cloth if necessary.  
6. Refill the tank as directed under “Initial Setup and  
Weekly Maintenance:  
1. Turn off the humidifier and unplug it from the wall outlet.  
2. Remove the tank unit by pulling it straight off the humidifier  
base.  
3. Turn the tank upside down and drain any water into a sink  
or tub. Shake the unit gently to remove any remaining water.  
4. Fill the water tank with a mixture of one (1) gallon of water  
and eight (8) ounces of white vinegar. Leave the mixture in  
the water tank for 20 minutes, giving the water tank a shake  
every few minutes. After 20 minutes, give the water tank a  
final shake and discard the mixture.  
5. Rinse the water tank several times with clean water. Leave  
the tank cap off to allow the water tank to dry completely.  
6. Wipe the surfaces of the humidifier base with a soft damp  
cloth.  
7. Once all the parts are clean and dry, reassemble the  
humidifier, refill the water tank, and resume use.  
note: The tank has built-in antimicrobial properties to inhibit  
the growth of bacteria, mold, and fungi that may affect the water  
in the tank. Daily and weekly maintenance is still necessary to  
prevent the growth of bacteria, mold, and fungi.  
5
©2010 Hunter Fan Company  
 
 
Maintenance  
3
Cleaning and Storage  
end of Season Maintenance:  
1. Follow the instructions for weekly maintenance before  
storing the unit.  
2. Ensure all parts are completely dry before storing the unit.  
3. Store the unit in a cool, dry place.  
4. Never store the unit with water in the tank.  
6
44061-01 • 08/02/2010  
 
Humidifier Assistance  
4
Troubleshooting  
Problem:  
Excessive noise  
Solution:  
1. Check the Water Tank to make sure it is properly seated on  
the base.  
2. Check the Water Tank to make sure there are no bubbles  
when the Water Tank is full and running. If there are bubbles,  
turn the unit OFF until the bubbling stops. When the bubbling  
has stopped, set the unit to the desired speed.  
Problem:  
Humidifier not working  
Solution:  
1. Make sure the Power Knob is not set to OFF.  
Problem:  
Mineral build-up on the Water Tank or Tray  
Solution:  
Problem:  
Humidity output and water usage decreased  
Solution:  
1. Check the Power Knob to make sure it is set to the desired  
humidity level and speed.  
2. Check the Water Tank to make sure there are no bubbles  
when the Water Tank is full and running. If there are bubbles,  
turn the unit OFF until the bubbling stops. When the bubbling  
has stopped, set the unit to the desired speed.  
3. Clean any components that have mineral build-up. Refer to  
7
©2010 Hunter Fan Company  
 
Humidifier Assistance  
4
Technical Support and Service Parts  
Technical Support  
If you need any assistance with setup, operation, or parts  
for your new Hunter Humidifier, please call us, our technical  
support staff is ready to help!  
USA: 1-888-830-1326  
canada: 1-866-268-1936  
Hours of operation are from 7:00 am to 7:00 pm Monday -  
Friday and 8:00 am to 5:00 pm on Saturday, Central Time. You  
may also contact us over the Internet at www.hunterfan.  
com or register your product at www.hunterfan.com/  
register and select your product under product registration.  
Service Parts  
Part #  
Part Name  
Part  
Tank  
89676-01-000  
Assembly  
8
44061-01 • 08/02/2010  
 
Humidifier Accessories  
5
Treatments  
Warm  
Mist  
Model  
Product  
evaporative Ultrasonic vaporizer  
Cleaning  
Cartridge  
31955  
Demineralization  
Cartridge  
31954  
31961  
Vapor Steam  
Vapor Pads  
31956  
31960  
Water Treatment  
Tablets  
Notes  
9
©2010 Hunter Fan Company  
 
Warranty  
6
3 Year Guarantee  
The Hunter Fan Company, Inc. makes the following warranty  
to the original residential user or consumer purchaser of the  
ultrasonic humidifier:  
If any part of The ultrasonic humidifier fails during the first  
3 (three) years from the date of purchase due to a defect in  
material or workmanship, we will provide a replacement part  
free of charge.  
If no replacement part can be provided, we will replace your  
Humidifier.  
IF THE ORIGINAL RESIDENTIAL USER OR CONSUMER  
PURCHASERCEASESTOOWNTHEULTRASONICHUMIDIFIER,  
THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH  
THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED  
TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR  
FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. THIS  
WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES.  
THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING  
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE  
IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS  
WARRANTY SET FORTH ABOVE.  
This warranty is voided if your ultrasonic humidifier is not  
purchased and used in the USA or Canada.  
This warranty excludes and does not cover defects, malfunctions,  
or failures of the humidifier which were caused by repairs by  
persons not authorized by us, use of parts, or accessories not  
authorized by us, mishandling, modifications, or damage  
to the humidifier while in your possession, or unreasonable  
use, including failure to provide reasonable and necessary  
maintenance. This warranty does not cover humidifiers used  
in commercial applications. There are no express or implied  
warranties as to commercial purchasers or users.  
To obtain service, contact the nearest Hunter authorized service  
center or the Hunter Fan Company Service Department, 7130  
Goodlett Farms Pkwy., Suite 400, Memphis, TN 38016, 1-888-  
830-1326. You will be responsible for insurance and freight or  
other transportation to our factory service center. We will return  
the humidifier freight prepaid to you. The humidifier should be  
properly packaged to avoid damage in transit since we will  
not be responsible for any such damage. Proof of purchase  
is required when requesting warranty service. The purchaser  
must present the sales receipt or other document that establishes  
proof of purchase.  
10  
44061-01 • 08/02/2010  
 
Warranty  
6
3 Year Guarantee  
IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE  
FOR DIRECT, INDIRECT, SPECIAL, CONSEQUENTIAL OR  
INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE  
OF THE HUMIDIFIER. YOUR SOLE REMEDY WILL BE REPAIR  
OR REPLACEMENT AS PROVIDED ABOVE. SOME AMERICAN  
STATES AND CANADIAN PROVINCES DO NOT ALLOW:  
• LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY  
LASTS;  
• THE EXCLUSION OR LIMITATION OF DIRECT, INDIRECT,  
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES;  
• THE EXCLUSION OR INVALIDITY OF EXPRESS OR IMPLIED  
WARRANTIES IF THE USER CEASES TO OWN THE HUMIDIFIER;  
• THE LIMITATION OF THE REMEDIES AND RECOURSES  
AVAILABLE TO THE PURCHASER; OR THE INVALIDITY OF AN  
EXPRESS WARRANTY WHEN A PRODUCT IDENTIFIED BY  
BRAND NAME IS NOT USED (UNLESS SPECIFIC CONDITIONS  
ARE FULFILLED);  
SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT  
APPLY TO YOU.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND  
YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM  
STATE TO STATE OR PROVINCE TO PROVINCE.  
Printed in china and Taiwan  
11  
©2010 Hunter Fan Company  
 

Graco Stroller PD194243C User Manual
Haier Air Conditioner 0010554405B User Manual
Haier TV DVD Combo L15C10A User Manual
Hans Grohe Indoor Furnishings 04180XX0 User Manual
Harbor Freight Tools Router 44914 User Manual
Hotpoint Electric Pressure Cooker EG53 User Manual
HP Hewlett Packard Network Router WHR HP AG108 User Manual
Husqvarna Trimmer 225L User Manual
Ice O Matic Ice Maker MFI User Manual
Impex Home Gym GB 7000AP User Manual