Installation Instructions
For Hunter Ceiling Fan Light Kits
Aurora Style
Preparing for Installation
CAUTIONS
1. Unassemble the fan switch housing as shown in
Figure 1.
·
·
Read entire text carefully before
beginning installation and save these
instructions.
2. Disconnect the upper and lower plug connectors
between the upper switch housing and lower
switch housing.
Note: Do not discard any parts. You will need to
replace it if you remove the light fixture in the
To reduce the risk of electrical shock,
install this light kit only on listed Hunter
ceiling fans type A through Z.
future.
Upper Switch
Housing
WARNINGS
·
To avoid possible electrical shock, before
installing light fixtures, disconnect power
by turning off the circuit breakers both
to the outlet box and to its associated wall
switch location. If you cannot lock the
circuit breakers in theoff position,
securely fasten a prominent warning
device, such as a tag, to the service panel.
Switch
Housing
Assembly
Screws
Lower
Switch
Housing
Switch
Housing
Cover
Plate
·
·
Connect house wiring to the fan before
attaching the light fixture to the fan.
All wiring must be in accordance with
national and local electrical codes. If you
are unfamiliar with wiring, you should use
a qualified electrician. Professional
installation is recommended.
Plug Button
Switch Housing
Assembly Screws
Figure 1 - Unassembling the fan switch housing
© 2003 Hunter Fan Company
1
41558-01 3-6-2003
Installing Globes and Bulbs
Thread the fan switch pull chain through the
grommetted hole in the light fixture bracket. Unfasten
the extra chain looped through the hole in the in the
lower mounting cap and attach it to the fan switch
pull chain. Repeat for light switch pull chain.
Refer to Figures 5, 6 and 7.
1. Install bulbs. Use 60W Max, A-15 bulbs.
2. Thread the fan switch pull chain through the hole in
the metal disk.
Hole in Lower
Mounting Cap
3. Place globe on pipe until flush against metal disk.
4. Thread the light switch pull chain through the large
center opening of the globe.
5. Thread the fan switch pull chain through the small
center opening in the globe.
Figure 6 - Attaching Fan Switch Pull Chain Extension
6. Place the cover plate up against the underside of
the globe. Pass light and fan switch pull chains
through the appropriate holes.
Fan Switch
Pull Chain
7. Thread the light switch pull chain through the
finial and screw the cap onto the pipe end until
tight.
Bulb
Socket
Pipe
Metal Disk
Globe
Light
Switch Pull
Chain
Grommetted
Hole
Lower Mounting Cap
Extra Chains
Figure 5 - Threading Fan Switch Pull Chain through
Grommet
Cover Plate
Finial
Figure 7 - Aurora Fixtures
Hunter Fan Company
2500 Frisco Avenue
Memphis, Tennessee 38125
United States of America
© 2003 Hunter Fan Company
3
41558-01 3-6-2003
|