Haier Water Heater QBJ1 130A58E User Manual

Solar Water Heater  
Instruction for use  
QBJ1-130A58E  
QBJ1-150A58E  
QBJ1-175A58E  
QBJ1-200A58E  
QBJ1-230A58E  
QBJ1-270A58E  
Please read thismanual before usage  
Retain it forfuture reference  
 
Content  
Technical data  
Features  
1
Appearance and parts  
Technical parameter  
1
1
Precautions  
2
Before use  
Notice  
3
3
Assembly Instruction  
The location  
4
4
5
5
Exterior and installation dimension  
Tank assembly  
Frame assembly  
Frame fastness  
5
6
7
7
8
9
Glass tube assembly  
Extraventricular plumbing instructions  
Indoor plumbing instructions  
Installation notice  
Pipelines thermal insulation notice  
The product with controller installation  
and using notice  
9
Using Instruction  
The operation method  
10  
Troubles treatment  
Packing list  
11  
11  
 
Technical data  
Features  
1. Inner cylinder: SUS 304 stainless steel, food grade.  
2. Insulation: Polyurethane foam, thickness-45 mm, good heat preservation effect.  
3. Outer shell: Aluminium / zinc coated steel sheet.  
4. Frame: Steady structure, shapely and durable .  
Appearance and parts  
Outer shell  
Cover  
Silicon seal ring  
Evacuated tubes  
Frame  
Foot cushion  
Base support  
Technical parameter  
QBJ1-130A58E QBJ1-150A58E QBJ1-175A58E QBJ1-200A58E QBJ1-230A58E QBJ1-270A58E  
Models  
Specification of tubes  
58mm 1800mm all glass evacuated tubular collector  
45  
Collector frame angle  
standard fixed  
16  
19  
22  
25  
30  
Number of tubes  
Aperture area  
14  
1.79m2  
130L  
2.07m2  
150L  
2.48m2  
175L  
2.90m2  
200L  
3.35m2  
230L  
4.03m2  
270L  
Usable water  
Total water volume  
169L  
195L  
228L  
262L  
300L  
354L  
Electric auxiliary  
heating  
Rated power: 1500W  
Water level sensor  
Using the water level sensor with the height of 360 mm  
Remarks:1. The warp of aperture area parameters is 3%. the warp ofusable water  
parameters is 5%. The permitted error limitof other parametersis 10%  
1
 
Precautions  
Precautions  
1.When using the water heater with electric heating, ensure that electric heating and  
electric tracing belt are closed.  
2. Avoiding irradiation without water after installation, it can't be used immediately, it  
should be sheltered.  
3. When supplying water at the first time, it should be operated in the morning or  
evening or the condition of short of light; avoid supplying water in strong sunshine,  
in order to prevent vacuum tubes bombing.  
4. If the water pressure isn't enough for water supply, please install an pressurize  
equipment.  
5. When the hot water is to be used, don't place the spray head face yourself until the  
water temperature is suitable.  
6. This product can supply the water depend on the fall of the tank and the water exit ,  
an pressurize equipment is recommended while the water couldn't be supplied  
normally due to the low fall.  
7. Do not supply cold water more than once in a low solar irradiance day.  
8. The energy is from solar, in the days that lack of solar such as rainy or snowy day,  
the temperature of the water may can't reach your demand, If there isn't electric heating ,  
it may not be used normally.  
9. Make sure the evacuated tubes clean, hose off the dust and dirt on the tubes and  
the reflector before the winter comes.  
10. The evacuated tubes resist as low temperature as -70 when tubes is emptied.  
The tank should remain filled up during continuously cloudy or snowing days in winter,  
in addition every two days the cold water in the tank should be changed to prevent the  
water in the tank from freezing which might damage the tubes.  
2
 
Before use  
Notice  
Please take time to read this manual and familiarize yourself with the function  
of this production.  
1. Please checkout the packinglist.  
2.If you fix electric auxiliary heating and controller, please select Haier  
equipped products.  
3. To avoid thescald, please mixthe hot andthe cold waterbefore use it.  
4. In order to protect the tank ,please don't refit or wall up the air supply pipe  
and the overflow pipe.  
3
 
Assembly Instruction  
The location:  
1. Please install the solar water heater in the area that avoid the thunder.  
2. Solar water heater angle range: east to south for 10 , west to south for 15  
.
3. There shouldn't be any hindrance in front of the heater ,or the distance should over  
L, L=H/tg(66.5 a) H:height of the hindrance; a: latitude of the area  
Notice: The solar water heater shall be installed by professional.  
Exterior and installation dimension:  
Installation dimension(mm)  
Exterior dimension(mm)  
Models  
QBJ1-130A58E  
QBJ1-150A58E  
QBJ1-175A58E  
QBJ1-200A58E  
QBJ1-230A58E  
QBJ1-270A58E  
Remarks: The permitted errorlimit of above parameters is 10%.  
A
H
B
D
4
 
Assembly Instruction  
Tank assembly  
1. Unpacking the tank, rip off the protection film. Uninstall the nut and cushion.  
2. Place tank onto tankbracket cradle, inserting protruding boltsinto holes.  
fasten with nuts.  
Notice:  
1. Rip off the protection film after the installationto avoid the destroy ofthe tank,  
and please don't use the sharp tool.  
2. Leave nuts loose sincesome adjustment may be necessaryafter fitting tubes.  
3. When assembling the water tank, keep the center line of vacuum tubes  
connecting holes parallel with thediagonal pillar of bracket.  
Frame assembly  
Please consult the accessional paper for figure of the frame and packing list in  
the packing of frame.  
Frame fastness  
1. Peg the feet of the heater into the earth with prepared iron or into the concrete  
brick with intumescent bolt.  
2. Adjust the height of the frame with the water-proof cushion to keep the tank  
aclinic and each foot balanceable.  
Notice:  
1. Make sure that the feet are all attach the floor closely, or it will cause the  
distortion of the frame.  
2. Please use the tight wire to fasten the tank and frame in the area that the  
typhoon occurred frequently.  
3. The installation of the solar water heater should be steadily or it will cause the  
destruction and the accident.  
5
 
Assembly Instruction  
Glass tube assembly  
1. Keep tubes out of the irradiation while assembling the unit or a scald may be  
caused.  
2. Place the rounded side of rubber seal downwardson the open end of tubes.(A)  
3. Insert the tube into base support of locating hole with gentle pressure and twisting  
motion.  
4. Holding the tube, fix base support into basebracket (B), insert tube into base  
support (C).  
5. Slide the tube down 1 cm, Slide blackrubber seal up the tubes until it sits flush  
with tank(D).  
6. Insert one tube on either end of thetank to achieve alignment of unit.  
Notice:  
1. Make sure the silicon seal ring are clean and well positioned.  
2. Place the rounded side of rubber seal downwards on open end of tube.  
Slide it down 10 cm. Wet open endof tube to make it easier to insert.  
Silicon seal ring  
Evacuated  
tubes  
Base support  
Base bracket  
Evacuated tubes  
Rubber seal  
C
A
Base bracket  
Base support  
Rubber seal  
hold position  
D
B
6
 
Assembly Instruction  
Extraventricular plumbing instructions  
Air supply pipe  
Over flow pipe  
Sensor  
Electric heating pipe  
Over flow hole (  
conect to the room  
Air supply hole(1/2 )  
forbidden to stem  
Electric heating flange  
Inlet/outlet hole (1/2 ), conect  
to the room  
Sensor hole 3/4  
A
a
b
QBJ1-130A58E  
QBJ1-150A58E  
QBJ1-175A58E  
QBJ1-200A58E  
QBJ1-230A58E  
QBJ1-270A58E  
A
b
a
Remarks: The permitted errorlimit of above parameters is 10%.  
Indoor plumbing instructions  
Solar water heater  
Connect the line  
of tracing belt  
Water level sensor  
Electric heating  
Controller  
Pre-burrided  
cord slot  
Tap water  
Hot water  
7
 
Assembly Instruction  
Installation notice  
1. Any alteration to the structure of the solar water heater may cause the trouble  
while using it.  
2. There are 5 connection methods of the waterpipe into the room, theyare smoke  
way, vent-pipe hole on the wall appropriative solar well prepared cannula  
and the first three kinds are common. Before the installation, our professional  
will consult the room's situation and choose the suitable location to bring you  
convenience. Aupend slope is necessary ,and should be wind-tight to prevent  
the rainy water or smell's entrance.  
3. Keep the placket of the overflow pipe downwards and fasten it so that the liquid  
can be lead to the cloaca directly, and please notice that the distance of the  
overflow pipe and the cloaca should less than 15cm. Don't placed the pipe  
optionally, so can avoid the water spatter.  
4. Don't install the valve in the pipeline to insure that the signal which shows the  
water is overflow will be worked normally.  
5.To avoid the water in the tank flow inverted, an unilateralism valve should be  
installed at the joint of the water pipe and the tap water.  
6. The installation project should be confirmed by ourprofessional service  
personnel when install several setsof these series.  
Contact to the water tank  
Other  
Please install another one-  
water heaters directional valve at the cold and hot  
water pipes if the solar tank is  
connected with other kinds of tanks  
to avoid the exceed pressure in  
these tanks flowing backwards to  
the solar tank and lead accidents.  
Tap water  
Hot water  
Illustration of connect the solar tank with other tanks  
8
 
Assembly Instruction  
Pipelines thermal insulation notice  
1.Outdoor pipelines should be thermal insulated according to local climate,  
bad thermal insulationmay lead toheat loss.  
2.The outlet used by electric tracing belt must ground reliably. The rated current  
of outlet is less than 10A, ensure is connected to plug reliably.  
3.Fixing electric tracing belt on cold and hot water pipes, in order to touch well,  
it should befixed with insulatingtape per 500mm.  
4.Waterproof should be tied up on thermal insulating pipes, for example  
aluminum foil cloth, glass fibre cloth, ethylene polyester waterprooffilm etc.  
Note: in coldarea, electric tracingbelt should befixed on outdoorpipelines.  
Otherwise when the environmental temperature is lower than -5 , any  
innocent thermal insulation will lead to the pipelines frozen, resulting in the  
pipelines damage.  
The product with controller installation and using notice  
1.If you fix controller, please select Haier products, otherwise our company  
won't be responsible for personal injure and damage of water heater.  
2.Haier has the controller used in domestic water heater, which has cord and  
plug, and they are connected well. Please select the electrical outlet of good  
quality, its rated current is not less than 16 A, and must ground reliably.  
3.The cord ofcontroller mustn't belayed in thermalinsulating layer ofpipelines,  
should be layed out of thermal insulating layer along the thermal insulating  
layer of pipelines.  
4.The location used to hang up controller should be reserved, suggesting  
height is 1.4 m~1.6m from ground.  
5.According to the controlling function you choose, supply and signal cords  
should be reserved between roofing and controller. Electric tracing belt needs  
RVV2 0.75 protective cord, electric needs RVV3 1 protective cord, water  
level display needsRVV3 0.12 protective cord, if electromagnetic valveis  
fixed on roofing, it needs RVV2 0.2 protective cord.  
6.If the controller you choose has water level display function, the water level  
sensor whose height is 360mm should be chosen.  
9
 
Assembly Instruction Using Instruction  
7.If the controller you choose has automatic water supply function,  
electromagnetic valve must be fixed in room horizontally; the direction of  
arrowhead labled on valve is the direction of water running out. Suggest fixing  
manual water supply side line, ensure that users can use water heater normally  
when the electromagnetic valve is damaged.  
8.If the supply cord is damaged, in order to avoid danger, it must be replaced by  
factory or maintenancedepartment or professionalstaff.  
9.Other requirements refer to controller introduction.  
The operation method  
1.K1 valve is open before using water, K2, K3 valves are closed  
2.The controller is set in the status of automatical water supply, the  
electromagnetic valve won't close until arriving at the set water level, and water  
supply is over  
3.Open K2 when you wantto use the water, open K3 to adjustthe temperature if it  
is too high.  
4.Close K2 and K3 when finish using the water.  
Air supply pipe  
Over flow pipe  
Sensor  
Electric heating pipe  
Controller  
Tap water  
Back  
valve  
Solenoid  
valve  
10  
 
Using Instruction  
Troubles treatment  
Possible reason  
Treatment  
Phenomenon  
Supply water according to the  
manual  
The tank is empty  
No water supply  
The pipeline or the connection  
is impeded  
Maintain the pipeline or clean  
the connection  
The controller  
can't reach the  
programmed  
level or there is  
no water  
The evacuated tubes have  
damaged  
Replacing the tubes  
The water supply is paused or low  
water pressure  
Waiting for the supplying again  
Maintain the pipeline and  
the connection  
The pipeline or the connection is  
Damaged  
Screw down the valve or  
replacing it  
Valve for water supply is unstuck  
or already damaged  
The evacuated tube can't work  
effectively for there are hindrance  
in front of it  
The temperature  
isn't high enough  
Change the location or move  
the hindranc  
Tidy the tube  
Too much ash on the tube  
Packing list  
Main parts  
Quantity  
Storage Storage tank  
tank  
Manual  
box  
Tank  
bracket  
box  
2
2
Left bracket support  
Right bracket support  
Evacuated tubes  
Frame box  
25  
1
30  
1
1
1
1
1
1
1
1
1
1
1
Controller box  
11  
 
 
Made in China  
Rev. 01  
Specific Number 0040500680F  
 

Grizzly Saw G4227 User Manual
Hamilton Beach Hot Beverage Maker 840055200 User Manual
HANNspree Flat Panel Television F651 12H1 User Manual
Hans Grohe Plumbing Product 06551XX0 User Manual
Harbor Freight Tools Sewing Machine 92966 User Manual
Hearth and Home Technologies Fan GFK21B User Manual
Honeywell Boiler L8151A User Manual
HP Hewlett Packard Cell Phone 50091 1 002 User Manual
Huawei Modem E219 User Manual
Hunter Fan Outdoor Ceiling Fan 42676 01 User Manual