Solar Water Heater
Instruction for use
QBJ1-130A58E
QBJ1-150A58E
QBJ1-175A58E
QBJ1-200A58E
QBJ1-230A58E
QBJ1-270A58E
Please read thismanual before usage
Retain it forfuture reference
Content
Technical data
Features
1
Appearance and parts
Technical parameter
1
1
Precautions
2
Before use
Notice
3
3
Assembly Instruction
The location
4
4
5
5
Exterior and installation dimension
Tank assembly
Frame assembly
Frame fastness
5
6
7
7
8
9
Glass tube assembly
Extraventricular plumbing instructions
Indoor plumbing instructions
Installation notice
Pipelines thermal insulation notice
The product with controller installation
and using notice
9
Using Instruction
The operation method
10
Troubles treatment
Packing list
11
11
Technical data
Features
1. Inner cylinder: SUS 304 stainless steel, food grade.
2. Insulation: Polyurethane foam, thickness-45 mm, good heat preservation effect.
3. Outer shell: Aluminium / zinc coated steel sheet.
4. Frame: Steady structure, shapely and durable .
Appearance and parts
Outer shell
Cover
Silicon seal ring
Evacuated tubes
Frame
Foot cushion
Base support
Technical parameter
QBJ1-130A58E QBJ1-150A58E QBJ1-175A58E QBJ1-200A58E QBJ1-230A58E QBJ1-270A58E
Models
Specification of tubes
58mm 1800mm all glass evacuated tubular collector
45
Collector frame angle
standard fixed
16
19
22
25
30
Number of tubes
Aperture area
14
1.79m2
130L
2.07m2
150L
2.48m2
175L
2.90m2
200L
3.35m2
230L
4.03m2
270L
Usable water
Total water volume
169L
195L
228L
262L
300L
354L
Electric auxiliary
heating
Rated power: 1500W
Water level sensor
Using the water level sensor with the height of 360 mm
Remarks:1. The warp of aperture area parameters is 3%. the warp ofusable water
parameters is 5%. The permitted error limitof other parametersis 10%
1
Precautions
Precautions
1.When using the water heater with electric heating, ensure that electric heating and
electric tracing belt are closed.
2. Avoiding irradiation without water after installation, it can't be used immediately, it
should be sheltered.
3. When supplying water at the first time, it should be operated in the morning or
evening or the condition of short of light; avoid supplying water in strong sunshine,
in order to prevent vacuum tubes bombing.
4. If the water pressure isn't enough for water supply, please install an pressurize
equipment.
5. When the hot water is to be used, don't place the spray head face yourself until the
water temperature is suitable.
6. This product can supply the water depend on the fall of the tank and the water exit ,
an pressurize equipment is recommended while the water couldn't be supplied
normally due to the low fall.
7. Do not supply cold water more than once in a low solar irradiance day.
8. The energy is from solar, in the days that lack of solar such as rainy or snowy day,
the temperature of the water may can't reach your demand, If there isn't electric heating ,
it may not be used normally.
9. Make sure the evacuated tubes clean, hose off the dust and dirt on the tubes and
the reflector before the winter comes.
10. The evacuated tubes resist as low temperature as -70 when tubes is emptied.
The tank should remain filled up during continuously cloudy or snowing days in winter,
in addition every two days the cold water in the tank should be changed to prevent the
water in the tank from freezing which might damage the tubes.
2
Before use
Notice
Please take time to read this manual and familiarize yourself with the function
of this production.
1. Please checkout the packinglist.
2.If you fix electric auxiliary heating and controller, please select Haier
equipped products.
3. To avoid thescald, please mixthe hot andthe cold waterbefore use it.
4. In order to protect the tank ,please don't refit or wall up the air supply pipe
and the overflow pipe.
3
Assembly Instruction
The location:
1. Please install the solar water heater in the area that avoid the thunder.
2. Solar water heater angle range: east to south for 10 , west to south for 15
.
3. There shouldn't be any hindrance in front of the heater ,or the distance should over
L, L=H/tg(66.5 a) H:height of the hindrance; a: latitude of the area
Notice: The solar water heater shall be installed by professional.
Exterior and installation dimension:
Installation dimension(mm)
Exterior dimension(mm)
Models
QBJ1-130A58E
QBJ1-150A58E
QBJ1-175A58E
QBJ1-200A58E
QBJ1-230A58E
QBJ1-270A58E
Remarks: The permitted errorlimit of above parameters is 10%.
A
H
B
D
4
Assembly Instruction
Tank assembly
1. Unpacking the tank, rip off the protection film. Uninstall the nut and cushion.
2. Place tank onto tankbracket cradle, inserting protruding boltsinto holes.
fasten with nuts.
Notice:
1. Rip off the protection film after the installationto avoid the destroy ofthe tank,
and please don't use the sharp tool.
2. Leave nuts loose sincesome adjustment may be necessaryafter fitting tubes.
3. When assembling the water tank, keep the center line of vacuum tubes
connecting holes parallel with thediagonal pillar of bracket.
Frame assembly
Please consult the accessional paper for figure of the frame and packing list in
the packing of frame.
Frame fastness
1. Peg the feet of the heater into the earth with prepared iron or into the concrete
brick with intumescent bolt.
2. Adjust the height of the frame with the water-proof cushion to keep the tank
aclinic and each foot balanceable.
Notice:
1. Make sure that the feet are all attach the floor closely, or it will cause the
distortion of the frame.
2. Please use the tight wire to fasten the tank and frame in the area that the
typhoon occurred frequently.
3. The installation of the solar water heater should be steadily or it will cause the
destruction and the accident.
5
Assembly Instruction
Glass tube assembly
1. Keep tubes out of the irradiation while assembling the unit or a scald may be
caused.
2. Place the rounded side of rubber seal downwardson the open end of tubes.(A)
3. Insert the tube into base support of locating hole with gentle pressure and twisting
motion.
4. Holding the tube, fix base support into basebracket (B), insert tube into base
support (C).
5. Slide the tube down 1 cm, Slide blackrubber seal up the tubes until it sits flush
with tank(D).
6. Insert one tube on either end of thetank to achieve alignment of unit.
Notice:
1. Make sure the silicon seal ring are clean and well positioned.
2. Place the rounded side of rubber seal downwards on open end of tube.
Slide it down 10 cm. Wet open endof tube to make it easier to insert.
Silicon seal ring
Evacuated
tubes
Base support
Base bracket
Evacuated tubes
Rubber seal
C
A
Base bracket
Base support
Rubber seal
hold position
D
B
6
Assembly Instruction
Extraventricular plumbing instructions
Air supply pipe
Over flow pipe
Sensor
Electric heating pipe
Over flow hole (
conect to the room
Air supply hole(1/2 )
forbidden to stem
Electric heating flange
Inlet/outlet hole (1/2 ), conect
to the room
Sensor hole 3/4
A
a
b
QBJ1-130A58E
QBJ1-150A58E
QBJ1-175A58E
QBJ1-200A58E
QBJ1-230A58E
QBJ1-270A58E
A
b
a
Remarks: The permitted errorlimit of above parameters is 10%.
Indoor plumbing instructions
Solar water heater
Connect the line
of tracing belt
Water level sensor
Electric heating
Controller
Pre-burrided
cord slot
Tap water
Hot water
7
Assembly Instruction
Installation notice
1. Any alteration to the structure of the solar water heater may cause the trouble
while using it.
2. There are 5 connection methods of the waterpipe into the room, theyare smoke
way, vent-pipe hole on the wall appropriative solar well prepared cannula
and the first three kinds are common. Before the installation, our professional
will consult the room's situation and choose the suitable location to bring you
convenience. Aupend slope is necessary ,and should be wind-tight to prevent
the rainy water or smell's entrance.
3. Keep the placket of the overflow pipe downwards and fasten it so that the liquid
can be lead to the cloaca directly, and please notice that the distance of the
overflow pipe and the cloaca should less than 15cm. Don't placed the pipe
optionally, so can avoid the water spatter.
4. Don't install the valve in the pipeline to insure that the signal which shows the
water is overflow will be worked normally.
5.To avoid the water in the tank flow inverted, an unilateralism valve should be
installed at the joint of the water pipe and the tap water.
6. The installation project should be confirmed by ourprofessional service
personnel when install several setsof these series.
Contact to the water tank
Other
Please install another one-
water heaters directional valve at the cold and hot
water pipes if the solar tank is
connected with other kinds of tanks
to avoid the exceed pressure in
these tanks flowing backwards to
the solar tank and lead accidents.
Tap water
Hot water
Illustration of connect the solar tank with other tanks
8
Assembly Instruction
Pipelines thermal insulation notice
1.Outdoor pipelines should be thermal insulated according to local climate,
bad thermal insulationmay lead toheat loss.
2.The outlet used by electric tracing belt must ground reliably. The rated current
of outlet is less than 10A, ensure is connected to plug reliably.
3.Fixing electric tracing belt on cold and hot water pipes, in order to touch well,
it should befixed with insulatingtape per 500mm.
4.Waterproof should be tied up on thermal insulating pipes, for example
aluminum foil cloth, glass fibre cloth, ethylene polyester waterprooffilm etc.
Note: in coldarea, electric tracingbelt should befixed on outdoorpipelines.
Otherwise when the environmental temperature is lower than -5 , any
innocent thermal insulation will lead to the pipelines frozen, resulting in the
pipelines damage.
The product with controller installation and using notice
1.If you fix controller, please select Haier products, otherwise our company
won't be responsible for personal injure and damage of water heater.
2.Haier has the controller used in domestic water heater, which has cord and
plug, and they are connected well. Please select the electrical outlet of good
quality, its rated current is not less than 16 A, and must ground reliably.
3.The cord ofcontroller mustn't belayed in thermalinsulating layer ofpipelines,
should be layed out of thermal insulating layer along the thermal insulating
layer of pipelines.
4.The location used to hang up controller should be reserved, suggesting
height is 1.4 m~1.6m from ground.
5.According to the controlling function you choose, supply and signal cords
should be reserved between roofing and controller. Electric tracing belt needs
RVV2 0.75 protective cord, electric needs RVV3 1 protective cord, water
level display needsRVV3 0.12 protective cord, if electromagnetic valveis
fixed on roofing, it needs RVV2 0.2 protective cord.
6.If the controller you choose has water level display function, the water level
sensor whose height is 360mm should be chosen.
9
Assembly Instruction Using Instruction
7.If the controller you choose has automatic water supply function,
electromagnetic valve must be fixed in room horizontally; the direction of
arrowhead labled on valve is the direction of water running out. Suggest fixing
manual water supply side line, ensure that users can use water heater normally
when the electromagnetic valve is damaged.
8.If the supply cord is damaged, in order to avoid danger, it must be replaced by
factory or maintenancedepartment or professionalstaff.
9.Other requirements refer to controller introduction.
The operation method
1.K1 valve is open before using water, K2, K3 valves are closed
2.The controller is set in the status of automatical water supply, the
electromagnetic valve won't close until arriving at the set water level, and water
supply is over
3.Open K2 when you wantto use the water, open K3 to adjustthe temperature if it
is too high.
4.Close K2 and K3 when finish using the water.
Air supply pipe
Over flow pipe
Sensor
Electric heating pipe
Controller
Tap water
Back
valve
Solenoid
valve
10
Using Instruction
Troubles treatment
Possible reason
Treatment
Phenomenon
Supply water according to the
manual
The tank is empty
No water supply
The pipeline or the connection
is impeded
Maintain the pipeline or clean
the connection
The controller
can't reach the
programmed
level or there is
no water
The evacuated tubes have
damaged
Replacing the tubes
The water supply is paused or low
water pressure
Waiting for the supplying again
Maintain the pipeline and
the connection
The pipeline or the connection is
Damaged
Screw down the valve or
replacing it
Valve for water supply is unstuck
or already damaged
The evacuated tube can't work
effectively for there are hindrance
in front of it
The temperature
isn't high enough
Change the location or move
the hindranc
Tidy the tube
Too much ash on the tube
Packing list
Main parts
Quantity
Storage Storage tank
tank
Manual
box
Tank
bracket
box
2
2
Left bracket support
Right bracket support
Evacuated tubes
Frame box
25
1
30
1
1
1
1
1
1
1
1
1
1
1
Controller box
11
Made in China
Rev. 01
Specific Number 0040500680F
|