HP Hewlett Packard Plumbing Product 4445 95 User Manual

Specifications Information and Replacement Parts Manual  
4445-95, 4446-95, 5570-95,  
5571-95, 5572-95  
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble,  
operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained  
in the General Operating Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury  
and/or property damage! Retain instructions for future reference.  
Vertical Sealless Sprayer/Washer  
Pumps  
Refer to form 1608-634-00 for General Operating and Safety Instructions and applicable Warranty.  
Description  
Vertical sealless sprayer/washer pumps are heavy duty industrial units designed for  
OEM, automotive and industrial washing machines, parts cleaners, spray booths and  
cooling towers. Pumps are immersion type; pump end must be immersed in liquid,  
motor must remain above liquid surface.  
All models feature 316 stainless steel semi-open clog resistant impeller, stainless steel  
shaft, steel shaft coupling, cast iron base and column, plated steel inlet screen, and a  
TEFC (Totally Enclosed Fan Cooled) electric motor. Motor has ball bearings. Heavy-  
duty steel universal mounting brackets included. Pump design eliminates a bottom  
bearing and a shaft seal on all models. Pumps handle liquids up to a maximum  
temperature of 200° F. Maximum ambient temperature 104° F. Liquid viscosity cannot  
exceed 100 SSU. These are manual units; no controls are supplied. For use with  
nonflammable liquids compatible with pump component materials.  
Specifications  
DRIVER  
NEMA DIS. Outlet  
RPM Frame (Inches)*  
Weight  
(Lbs.)  
78  
73  
165  
150  
130  
Model  
HP Power Supply  
4445-95  
4446-95  
3
3
230 VAC, 60 Hz. 1-phase  
230 VAC, 60 Hz. 3-phase  
3450 56C  
3450 56C  
1-½  
1-½  
1-½  
1-½  
1-½  
5570-95 10 230/460 VAC, 60 Hz. 3-phase 3450 184JM  
5571-95 7.5 230/460 VAC, 60 Hz. 3-phase 3450 184JM  
5572-95  
5
230/460 VAC, 60 Hz. 3-phase 3450 184JM  
NOTE: Driver data is subject to change without notice, see label on driver for actual specifications.  
(*) Standard NPT (female) pipe thread  
Performance Chart  
GPM of Water at Total Head in Feet  
Max.  
Model  
HP  
3
3
60  
80  
80  
*
70  
55  
55  
115  
80  
25  
25  
100  
90  
-
-
100  
-
-
50  
110  
120  
130  
140  
150  
Head†  
85 ft.  
85 ft.  
110 ft.  
4445-95  
4446-95  
5572-95  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5
80  
5571-95 7.5  
5570-95 10  
*
*
*
*
140  
*
125  
162  
110  
150  
90  
135  
70  
120  
40  
95  
-
70  
-
40  
140 ft.  
160 ft.  
(*) Operation of pumps beyond range indicated will result in reduced pump life, pump damage and/or motor damage.  
() Shut-off; convert to psi, multiply by specific gravity and divide by 2.31  
Installation  
3. Position pump in tank or reservoir.  
Position mounting brackets, align  
pipe clearance hole with pump  
discharge outlet.  
(5570 series pumps)  
1. (5570 series pumps) Remove  
shipping fixture (Ref. No. 19) that  
holds the drive shaft to the base  
before installing pump.  
4. Adjust lower fasteners (Ref. No. 4)  
to bottom of mounting brackets.  
Secure pump to mounting brackets  
with upper fasteners (Ref. No. 4).  
(4445 series pumps)  
2. Pump must be installed with its  
base supporting the entire weight of  
the pump.  
CAUTION Mounting brackets are  
not designed to support the  
pump’s weight. Brackets are  
designed to prevent tipping.  
4. Assemble one piece of sponge tape  
(Ref. No. 25) to each clamp bracket  
(Ref. No. 24). Attach clamp brackets to  
mounting brackets with fasteners  
provided (Ref. Nos. 26 and 27). This  
will fix the column (Ref. No. 3) in  
position.  
5. Secure mounting brackets to tank  
or reservoir. Install an appropriate  
fastener in each hole or slot provided.  
6. Install the balance of the system.  
5570-250-00  
03/2006  
 
3
 
Repair Parts List  
Ref.  
Part Numbers For Models:  
No.  
1
2
3
4
5
Description  
Motor  
Coupling  
Column  
Washer  
Fastener  
4445-95  
1626-075-00  
4430-143-00  
4430-032-09  
*
4446-95  
1626-076-00  
4430-143-00  
4430-032-09  
*
*
Qty.  
1
1
1
4
4
*
6
7
8
Fastener  
Washer  
Fastener  
*
*
*
*
*
*
3
10  
7
9
Impeller shim set (See 14)  
10  
Volute cover  
4445-020-09  
4440-020-01  
1
11  
12  
13  
14  
15  
Volute spacer plate  
Fastener  
Shaft  
Impeller, Includes 9 & 15  
Impeller nut  
4445-060-09  
*
4445-140-00  
4445-010-98  
1784-001-00  
4445-060-09  
*
4445-140-00  
4445-010-98  
1784-001-00  
1
2
1
1
1
16  
17  
18  
19  
20  
Gasket  
4440-300-00  
4445-001-95  
N/A  
N/A  
Not available  
4440-300-00  
4445-001-95  
N/A  
N/A  
Not available  
1
1
1
-
Volute base, Includes 18  
Debris screen (See 17)  
N/A  
Shaft support  
1
21  
Δ
Support plate  
Mounting bracket kit  
4445-090-09  
4420-90  
4445-090-09  
4420-90  
1
1
(Δ) Not shown.  
(*) Standard hardware item, available locally.  
N/A Not applicable to this model.  
4
5570-250-00  
03/2006  
 
 

Graco Water Dispenser 710 User Manual
Honeywell Air Cleaner HCM350 User Manual
Hoshizaki Dishwasher JWE 620UA 6B User Manual
HP Hewlett Packard Plumbing Product J9020A User Manual
HP Hewlett Packard Portable Media Storage 31X User Manual
HP Hewlett Packard Security Camera XP256 User Manual
Hubbell Switch LMTS User Manual
Husqvarna Tiller TS200FR User Manual
Husqvarna Webcam FS305 User Manual
IFB Appliances Microwave Oven 17PG1S User Manual