1
2
3
Overview..........................................................................................................................................5  
BroadWorks Validation Package Support Level.......................................................................6  
Device Capabilities and Known Interoperability Issues...........................................................7  
3.1 Capabilities....................................................................................................................................7  
3.2 Interoperability Issues...................................................................................................................9  
4
5
6
BroadWorks Device Identity/Profile..........................................................................................10  
BroadWorks Device Type...........................................................................................................11  
Configuration................................................................................................................................12  
6.1 System Level Configuration...................................................................................................... 13  
6.2 Subscriber Level Configuration Parameters............................................................................ 14  
7
Enhanced IP Phone Configuration............................................................................................15  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 4 OF 25  
 
1
Overview  
This document describes the configuration procedures required for a Grandstream GXW-  
4004 / GXW-4008 / HT-502 to make full use of the capabilities of BroadWorks.  
The GXW-4004 / GXW-4008 / HT-502 are a few of the many access devices that  
interoperate with BroadWorks.  
The GXW-4004 / GXW-4008 / HT-502 uses the Session Initiation Protocol (SIP) to  
communicate with BroadWorks for call control. It also translates voice to audio packets for  
transmission across a packet network.  
This guide describes the specific configuration items that are important for use with  
BroadWorks. It does not describe the purpose and use of all configuration items on the  
GXW-4004 / GXW-4008 / HT-502. For those details, see the GXW-4004 / GXW-4008 /  
HT-502 User Manual supplied by Grandstream 1.a)i.[1]  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 5 OF 25  
 
2
BroadWorks Validation Package Support Level  
Devices are validated according to BroadWorks Validation Packages. Each package  
validates a subset of features or items. This section describes the device’s support level  
for a BroadWorks Validation Package as well as the features or items in the package that  
are not supported. For specific issues, see section 3.2 Interoperability Issues. For a  
complete list of items validated per package, see Appendix B: BroadWorks Validation  
Package Test Items.  
BroadWorks Package  
Basic Call  
Support Level  
Full  
Items Not Supported  
BroadWorks Enhanced Services  
Partial  
Ring Splash  
Advanced Call Control (Talk, Auto-  
Answer)  
DUT Services – Call Control  
Partial  
Partial  
Network Conference 3-Way  
Network Conference N-Way  
DUT Services – Registration and  
Authentication  
BroadWorks Authentication  
DUT Services – FAX  
DUT Services – Busy Lamp Field  
Redundancy  
Full  
None  
Full  
SBC/ALG  
Full  
Shared Call Appearance  
Video  
None  
None  
Full  
TCP  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 6 OF 25  
 
3
Device Capabilities and Known Interoperability Issues  
This section describes the features supported by the GXW-4004 / GXW-4008 / HT-502,  
as well as BroadWorks interoperability issues and impact. The following table describes  
capabilities.  
Verified Revisions shows the results of partner (vendor) testing of a specific BroadWorks  
version with a specific partner’s device under test (DUT) version.  
Compatible Revisions indicates the maintenance versions that should interface properly  
with BroadWorks.  
3.1 Capabilities  
Device Type  
Generic SIP Smart (Proxy Addr)  
Lines and Appearances  
GXW-4004: 4 lines 1 appearances per line  
GXW-4008: 8 lines 1 appearances per line  
HT-502: 2 lines 1 appearances per line  
Speaker/Power/Bridge  
Verified Revisions  
No/No/Yes  
BroadWorks Release 14.0  
GXW-4004: Grandstream 1.0.0.39  
GXW-4008: Grandstream 1.0.0.39  
HT-502: Grandstream 1.0.0.39  
Compatible Revisions  
BroadWorks Release 14.0  
Grandstream Any maintenance version of GXW-  
4004/GXW-4008/HT-502 1.0.0.39  
SIP Proxy FQDN DNS Lookup  
(A, SRV, NAPTR)  
A, SRV  
Outbound Proxy Configurable  
Yes  
Outbound Proxy FQDN DNS Lookup  
(A, SRV, NAPTR)  
A, SRV  
BroadWorks Redundancy Enabled  
BroadWorks Shared Call Appearance  
Yes  
N/A  
BroadWorks Enhanced IP Phone  
Configuration  
Partial  
Device Services  
Call Forwarding, Attended/Blind Call Transfer, 3-way  
Call, Call Waiting, Call Hold, Call Return.  
Device Call Control  
Device-Controlled  
(Device-Controlled or Flash INFO-  
based)  
Codecs  
PCMU, PCMA, G723.1 G729A/B/E, iLBC, G726-  
16/24/32/40  
RFC 2833 DTMF  
T.38 Fax  
Yes  
Yes  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 7 OF 25  
 
TCP  
TLS  
Yes  
Yes  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 8 OF 25  
 
3.2 Interoperability Issues  
This section lists the known interoperability issues between BroadWorks and partner  
release(s). For more information on issues related to the particular software release, see  
the partner release notes (generally, this should only be for GA partner releases).  
Issue Tracking  
Number  
Issue Title and Description  
BroadWorks Release 14  
Partner Releases  
1025 - 61  
1025 -119  
Broadworks to DUT, Do Not Disturb (DND) ring splash  
X
X
DUT does not play a ring splash. DUT driver does not support ring  
splash.  
DUT to BroadWorks via Primary Application Server, DUT  
Currently Served by Secondary Application Server  
DUT does not always contact the primary server first for INVITE. It  
relies on the OPTIONS message from BroadWorks to failback.  
When DUT is registered on secondary server and the primary  
server becomes available and sends an OPTIONS request, DUT  
will send INVITE to the primary server.  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 9 OF 25  
 
4
BroadWorks Device Identity/Profile  
BroadWorks configurable device identify/profile is introduced in BroadWorks Release 14.0.  
This section applies only to BroadWorks Release 14.0 and later.  
The following table identifies the required BroadWorks device identity/profile settings for  
interoperability between the GXW-4004/GXW-4008/HT-502 and BroadWorks. For an  
explanation of the profile parameters, refer to the BroadWorks Device Inventory Guide  
1.a)i.[4].  
For most of the parameters below, an “X” indicates the parameter function is supported  
and/or required. If the item is blank, it is not supported.  
Grandstream GXW-4004/GXW-4008/HT-502 Identify/Device Profile  
Signaling Address Type  
Number of Lines  
Intelligent Proxy Addressing  
GXW-4004: 4 lines  
GXW-4008: 8 lines  
HT-502: 2 lines  
Ringback Tone/ Early Media  
Support  
Local Ringback – No Early Media  
Registration Capable  
Static Registration Capable  
E.164 Capable  
X
Trusted  
Authentication Override  
Video Capable  
RFC 3264 Hold  
X
Route Advance  
Wireless Integration  
PBX Integration  
Use Business Trunking Contact  
Forwarding Override  
Conference Device  
Music On Hold Device  
Web Based Configuration URL  
Auto Configuration Type  
Reset Event  
2 Config file  
checkSync  
Enable Monitoring  
CPE System File Name  
Device File Format  
gxwSystem.txt / htSystem.txt  
%BWMACADDRES%.txt  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 10 OF 25  
 
5
BroadWorks Device Type  
This section applies to BroadWorks Release 13.0 and before.  
The following BroadWorks device type should be used for Grandstream GXW-4004 /  
GXW-4008 /HT-502.  
Grandstream GXW-4004  
Grandstream GXW-4008  
Grandstream HT-502  
The above device types require BroadWorks Release 14 MP<TBD>. If the BroadWorks  
system is currently at a lower patch level, either apply the necessary patch or use the  
following generic device type until the system can be patched accordingly.  
Generic SIP Smart (Proxy Addr)  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 11 OF 25  
 
6
Configuration  
Grandstream GXW-4004 / GXW-4008 / HT-502 can be configured via Web GUI Interface  
as well as via Configuration File through TFTP or HTTP.  
The GXW-4004 / GXW-4008 / HT-502 accepts configuration files in a proprietary binary  
format which is produced by the Grandstream configuration tool. The configuration tool  
creates a device configuration file based on a configuration template and the device’s  
MAC address. All Grandstream products’ sample configuration templates are available on  
Grandstream’s web site. A configuration template file contains all configuration  
parameters available for a product, with comments describing allowed values of the  
parameters. For a detailed parameter list, please refer to the corresponding firmware  
release configuration template 1.a)i.[2].  
When Grandstream device boots up or reboots, it will issue request for a binary  
configuration file named “cfgxxxxxxxxxxxx”, where “xxxxxxxxxxxx” is the LAN MAC  
address of the device, i.e., “cfg000b820102ab”. The configuration file name should be in  
lower cases.  
Grandstream offers free Configuration File generator software in both Linux/Unix and  
Windows platform. Both Configuration File Generators can be downloaded from  
1.a)i.[2].  
The following examples describe how to set the parameters using a configuration file.  
The GXW-4004 / GXW-4008 / HT-502 should be configured to load the configuration file  
each time it resets or re-synchronizes. For detailed information on automated provisioning,  
please check the GXW-4004 / GXW-4008 / HT-502 User Manual 1.a)i.[1] and the  
Grandstream configuration tool user guide 1.a)i.[2].  
The capabilities of the GXW-4004 / GXW-4008 / HT-502 have been verified for use with  
BroadWorks based on the settings described in the following table. For more information  
on the meaning, purpose, and applicability of the individual configuration items, see the  
GXW-4004 / GXW-4008 / HT-502 configuration template 1.a)i.[2].  
Configuration Files  
Files Provided by Partner  
Level  
Description  
gxw4004prog.bin/gxw4004core.bin/gxw4  
004boot.bin/gxw4004base.bin  
System  
Contains the device firmware load.  
gxw4008prog.bin/gxw4008core.bin/gxw4  
008boot.bin/gxw4008base.bin  
ht502prog.bin/ht502core.bin/ht502boot.bi  
n/ht502base.bin  
GXW-4004 / GXW-4008 / HT-502  
Configuration Template  
System and  
Subscriber  
Contains configurable parameters that  
apply to all devices in a given  
deployment.  
Example: gxw400x_config_1.0.0.39.txt  
ht502_config_1.0.0.39.txt  
cfgMAC  
System and  
Subscriber  
Binary configuration file generated  
from configuration template and an  
individual device’s MAC address  
Example: cfg000b82000000  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 12 OF 25  
 
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 13 OF 25  
 
6.1 System Level Configuration  
This section describes system-wide configuration items that are generally required for  
each GXW-4004 / GXW-4008 / HT-502 to work with BroadWorks. Subscriber-specific  
settings are described in the next section.  
Step  
Command  
Purpose  
System Configuration File <system-wide configuration file name>  
Set SIP Proxy/Domain.  
Step 1  
Set the GXW-4004 / GXW-4008  
/ HT-502 SIP server to the Fully  
Qualified Domain Name (FQDN)  
for the BroadWorks Application  
Server cluster.  
SIP Server = as.broadworks.net  
The domain must match the  
domain configured for the  
BroadWorks subscriber’s  
line/port domain.  
Set Outbound Proxy.  
Step 2  
Set the outbound proxy to the  
session border controller (SBC)  
if one is deployed between the  
GXW-4004 / GXW-4008 / HT-  
502 and BroadWorks.  
OutBound Proxy =  
sbc.broadworks.net  
If there are redundant SBCs, set  
it to the FQDN for the SBC  
cluster.  
Enable DNS SRV lookup.  
Step 3  
Step 4  
Step 5  
Enable DNS SRV lookups.  
Use DNS SRV = “Yes”  
Set register mode.  
Enable SIP register.  
SIP Registration = “Yes”  
Set SIP Timers.  
The default registration period is  
60 minutes.  
Register Expiration = 60  
Enable negotiated DTMF type.  
Step 6  
Step 7  
Set the GXW-4004 / GXW-4008  
/ HT-502 to enable inband or  
RFC 2833 negotiated DTMF.  
Send DTMF = “via RTP (RFC2833)”  
Configure dialplan.  
Example:  
Configure the GXW-4004 /  
GXW-4008 / HT-502 dial plan  
according to the locale.  
Dial Plan = “{ x+ }”  
The dial plan shown is the  
device default dial plan – any  
number is allowed.  
Disable local feature code  
services.  
Step 8  
Disable feature access codes  
controlled by the device.  
Enable Call Features = “No”  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 14 OF 25  
 
6.2 Subscriber Level Configuration Parameters  
This section identifies the device-specific parameters, including registration and  
authentication. These settings must be unique across devices in order to be matched with  
the settings for a BroadWorks subscriber.  
Provisioning a subscriber to register with BroadWorks allows calls to terminate to the  
subscriber’s line. Registration requires that a unique address of record (AoR) is  
provisioned on BroadWorks and the phone; provisioning an AoR on BroadWorks consists  
of setting the line/port parameter to a unique value within the Application Server cluster.  
Grandstream GXW-4004 / GXW-4008 / HT-502 supports four SIP accounts (lines), eight  
SIP accounts, and two SIP accounts respectively. The follow example shows how to  
configure subscriber elements for an account.  
Step  
Command  
Purpose  
Subscriber Configuration Items  
Set Register User ID for each  
line.  
Step 1  
Step 2  
The register user ID must  
correspond with the line/port  
setting on BroadWorks.  
Example:  
SIP User_ID = "2405551111" ;  
Enable SIP Authentication for  
each line.  
If the Authentication service is  
configured on BroadWorks, these  
parameters must be configured to  
match the BroadWorks settings.  
Example:  
Authenticate ID =  
Authenticate Password =  
"welcome" ;  
Configure display name for each  
line.  
Step 3  
Step 4  
For each line, configure the name  
to be displayed on the device.  
Example:  
Name = “Claire Smith” ;  
Select SIP Profile for each line.  
Example:  
Set SIP Profile or each line.  
Profile ID = Profile 1  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 15 OF 25  
 
7
Enhanced IP Phone Configuration  
Enhanced IP Phone Configuration is a BroadWorks feature that enables automatic  
generation of device configuration files, given administrator-supplied templates.  
For more information on the Enhanced IP Phone Configuration feature, see the Enhanced  
IP Phone Configuration Guide 1.a)i.[3].  
NOTE: BroadSoft does not manage or distribute template files for use with the Enhanced IP  
Phone Configuration feature. Obtain template files from Grandstream or use the configuration  
files obtained from Grandstream for the specific GXW-4004 / GXW-4008 / HT-502 firmware  
release to create template files appropriate for your installation.  
Since the GXW-4004 / GXW-4008 / HT-502 SIP phones require the configuration files be  
converted into a binary format, an extra step must be performed when using this feature. After  
the configuration files have been sent to the TFTP server and before the phone is reset, the  
configuration files must be converted to binary format using Grandstreams configuration tool. .  
For detailed information on automated provisioning, please check the Grandstream configuration  
tool user guide 1.a)i.[2].  
The GXW-4004 / GXW-4008 / HT-502 use only a phone-specific file to configure the  
device. However, the Enhanced IP Phone Configuration feature requires a system and a  
phone-specific file for each device. To satisfy the system file requirement, an empty file  
(gxwDefault.txt, htDesfult.txt) will need to be uploaded to BroadWorks as the system file.  
This file will be sent to the FTP server but will not actually be used for the configuration file  
generation. The group template file is used to build the configuration files for the devices  
of this device type assigned to the group. For a sample GXW-4004 / GXW-4008 / HT-502  
group template file, see Appendix A.  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 16 OF 25  
 
Appendix A: Sample GXW-4004 / GXW-4008 / HT-502 Configuration Files  
NOTE: The following samples are examples and should be used as a reference only. DO NOT CUT  
AND PASTE THESE EXAMPLES TO GENERATE YOUR CONFIGURATION FILES. Use the  
configuration files obtained from Grandstream with the specific release to generate your configuration  
files.  
System Default Parameters  
NOTE: This is an example file and should be used for reference only.  
# SIP Default Generic Configuration Parameters  
##################################  
# Profile/Account 1  
#
##################################  
# Profile Active. 0 - no, 1 - yes  
P271 = 1  
# SIP Server  
P47 = as.broadworks.net  
# Outbound Proxy  
P48 = sbc.broadworks.net  
# Use DNS SRV. 0 - no, 1 - yes.  
P103 = 1  
# SIP Registration. 0 - no, 1 - yes  
P31 = 1  
# Register Expiration (in minutes. default 1 hour, max 45 days)  
P32 = 60  
# DTMF via RTP (RFC2833). 0 - no, 1 - yes  
P851 = 1  
# Dial Plan.  
P4200 = { x+ }  
# Enable Call Features. 0 - no, 1 – yes  
P191 = 0  
###################################  
# Profile/Account 2  
#
###################################  
# Profile Active. 0 - no, 1 - yes  
P401 = 1  
# SIP Server  
P747 = as.broadworks.net  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 17 OF 25  
 
# Outbound Proxy  
P748 = sbc.broadworks.net  
# Use DNS SRV. 0 - no, 1 - yes.  
P702 = 1  
# SIP Registration. 0 - no, 1 – yes  
P731 = 1  
# Register Expiration (in minutes. default 1 hour, max 45 days)  
P732 = 60  
# DTMF via RTP (RFC2833). 0 - no, 1 - yes  
P861 = 1  
# Dial Plan.  
P4201 = { x+ }  
# Enable Call Features. 0 - no, 1 – yes  
P751 = 0  
Phone-Specific Parameters:  
NOTE: This is an example file and should be used for reference only.  
# SIP Device-specific Configuration Parameters  
##################################  
# HT-502 Account 1  
#
##################################  
# SIP User ID  
P35 = 2405551111  
# Authenticate ID  
# Authenticate password  
P34 = welcome  
# Display Name  
P3 = Claire Smith  
##################################  
# HT-502 Account 2  
#
##################################  
# Account 2 SIP User ID  
P735 =  
# Authenticate ID  
P736 =  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 18 OF 25  
 
# Authenticate Password  
P734 =  
# Display Name  
P703 =  
############################  
# GXW-4004/GXW-4008  
#
############################  
# FXS Port 1  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4060 =  
P4090 =  
P4120 =  
P4180 =  
P4150 =  
# FXS Port 2  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4061 =  
P4091 =  
P4121 =  
P4181 =  
P4151 =  
# FXS Port 3  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4062 =  
P4092 =  
P4122 =  
P4182 =  
P4152 =  
# FXS Port 4  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4063 =  
P4093 =  
P4123 =  
P4183 =  
P4153 =  
#####################################################  
# The following 4 ports belong to GXW-4008 only  
#
#####################################################  
# FXS Port 5  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4064 =  
P4094 =  
P4124 =  
P4184 =  
P4154 =  
# FXS Port 6  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 19 OF 25  
 
Profile 1, 1 - Profile 2)  
P4065 =  
P4095 =  
P4125 =  
P4185 =  
P4155 =  
# FXS Port 7  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4066 =  
P4096 =  
P4126 =  
P4186 =  
P4156 =  
# FXS Port 8  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4067 =  
P4097 =  
P4127 =  
P4187 =  
P4157 =  
Group Template File: GXW-GroupTemplate.txt /HT- GroupTemplate.txt  
NOTE: This is an example file and should be used for reference only.  
# SIP Default Generic Configuration Parameters  
##################################  
# Profile/Account 1  
#
##################################  
# Profile Active. 0 - no, 1 - yes  
P271 = 1  
# SIP Server  
P47 = as.broadworks.net  
# Outbound Proxy  
P48 = sbc.broadworks.net  
# Use DNS SRV. 0 - no, 1 - yes.  
P103 = 1  
# SIP Registration. 0 - no, 1 - yes  
P31 = 1  
# Register Expiration (in minutes. default 1 hour, max 45 days)  
P32 = 60  
# DTMF via RTP (RFC2833). 0 - no, 1 - yes  
P851 = 1  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 20 OF 25  
 
# Dial Plan.  
P4200 = { x+ }  
# Enable Call Features. 0 - no, 1 – yes  
P191 = 0  
###################################  
# Profile/Account 2  
#
###################################  
# Profile Active. 0 - no, 1 - yes  
P401 = 1  
# SIP Server  
P747 = as.broadworks.net  
# Outbound Proxy  
P748 = sbc.broadworks.net  
# Use DNS SRV. 0 - no, 1 - yes.  
P702 = 1  
# SIP Registration. 0 - no, 1 – yes  
P731 = 1  
# Register Expiration (in minutes. default 1 hour, max 45 days)  
P732 = 60  
# DTMF via RTP (RFC2833). 0 - no, 1 - yes  
P861 = 1  
# Dial Plan.  
P4201 = { x+ }  
# Enable Call Features. 0 - no, 1 – yes  
P751 = 0  
###################################################  
# SIP Device-specific Configuration Parameters  
#
###################################################  
##################################  
# HT-502 Account 1  
#
##################################  
# SIP User ID  
P35 = %BWLINEPORT-1%  
# Authenticate ID  
P36 = %BWAUTHUSER-1%  
# Authenticate password  
P34 = %BWAUTHPASSWORD-1%  
# Display Name (John Doe)  
P3 = %BWCLID-1%  
##################################  
# HT-502 Account 2  
#
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 21 OF 25  
 
##################################  
# Account 2 SIP User ID  
P735 = %BWLINEPORT-2%  
# Authenticate ID  
P736 = %BWAUTHUSER-2%  
# Authenticate Password  
P734 = %BWAUTHPASSWORD-2%  
# Display Name  
P703 = %BWCLID-2%  
############################  
# GXW-4004/GXW-4008  
#
############################  
# FXS Port 1  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4060 = %BWLINEPORT-1%  
P4090 = %BWAUTHUSER-1%  
P4120 = %BWAUTHPASSWORD-1%  
P4180 = %BWCLID-1%  
P4150 =  
# FXS Port 2  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4061 = %BWLINEPORT-2%  
P4091 = %BWAUTHUSER-2%  
P4121 = %BWAUTHPASSWORD-2%  
P4181 = %BWCLID-2%  
P4151 =  
# FXS Port 3  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4062 = %BWLINEPORT-3%  
P4092 = %BWAUTHUSER-3%  
P4122 = %BWAUTHPASSWORD-3%  
P4182 = %BWCLID-3%  
P4152 =  
# FXS Port 4  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4063 = %BWLINEPORT-4%  
P4093 = %BWAUTHUSER-4%  
P4123 = %BWAUTHPASSWORD-4%  
P4183 = %BWCLID-4%  
P4153 =  
#####################################################  
# The following 4 ports belong to GXW-4008 only  
#
#####################################################  
# FXS Port 5  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 22 OF 25  
 
P4064 = %BWLINEPORT-5%  
P4094 = %BWAUTHUSER-5%  
P4124 = %BWAUTHPASSWORD-5%  
P4184 = %BWCLID-5%  
P4154 =  
# FXS Port 6  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4065 = %BWLINEPORT-6%  
P4095 = %BWAUTHUSER-6%  
P4125 = %BWAUTHPASSWORD-6%  
P4185 = %BWCLID-6%  
P4155 =  
# FXS Port 7  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4066 = %BWLINEPORT-7%  
P4096 = %BWAUTHUSER-7%  
P4126 = %BWAUTHPASSWORD-7%  
P4186 = %BWCLID-7%  
P4156 =  
# FXS Port 8  
# SIP USER ID, Authenticate ID, Password, Display Name, Profile ID (0 -  
Profile 1, 1 - Profile 2)  
P4067 = %BWLINEPORT-8%  
P4097 = %BWAUTHUSER-8%  
P4127 = %BWAUTHPASSWORD-8%  
P4187 = %BWCLID-8%  
P4157 =  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 23 OF 25  
 
Appendix B: BroadWorks Validation Package Test Items  
The following table describes the items tested in each BroadWorks Validation Package.  
BroadWorks Validation Package  
Items Supported  
Basic Call  
Basic Call Origination / Termination  
Call Failure Codes  
Session Audit  
Ringback  
Dial Plan  
Inband DTMF  
RFC 2833/Negotiation  
Codec Renegotiation  
BroadWorks Enhanced Services  
Basic CommPilot Call Manager Functions  
Voice Messaging Audio MWI  
Voice Messaging Visual MWI  
Ring Splash  
Priority Alerting  
Priority Call Waiting  
Alternate Numbers  
Advanced Call Control  
Anonymous Call  
Remote Restart  
Call Park Retrieve – Answer with Hold  
DUT Services – Call Control  
Call Waiting  
Call Hold  
Blind Transfer  
Attended Transfer  
3-Way Call  
Network Conference 3-Way  
Network Conference N-Way  
DUT Services – Registration and  
Authentication  
Authenticated Registration  
Maximum Registration  
Minimum Registration  
Rejected Registration  
Authenticated Origination  
Authenticated Re-INVITE  
Authenticated REFER  
BroadWorks Authentication  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 24 OF 25  
 
BroadWorks Validation Package  
Items Supported  
DUT Services - FAX  
FAX Passthrough  
FAX T38  
DUT Services – Busy Lamp Field  
Redundancy  
Basic BLF  
DNS  
Registration Failover  
Call Setup Failover  
Mid-Call Failover  
SBC/ALG  
Registration  
Call Origination  
Call Termination  
Shared Call Appearance  
Line Seize  
Line Lamp Management  
Line Hold/Retrieve  
Multiple Call Arrangement  
SCA Bridging  
Video  
TCP  
Integrated Video Phone  
Video Add-On  
Basic  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 25 OF 25  
 
References  
[1] Grandstream Networks, Inc. 2007. GXW-400X / HT-502 User Manual. Download  
at  
AND GUI Interfaces  
[2] Grandstream Networks, Inc. 2007. Grandstream Configuration Tool and Templates.  
[3] BroadSoft, Inc. 2006. BroadWorks Enhanced IP Phone Configuration Guide,  
Release 14.0. Available from the BroadSoft KnowledgeBase at  
[4] BroadSoft, Inc. 2006. BroadWorks Device Inventory Guide, Release 14.0.  
Available from the BroadSoft KnowledgeBase at  
[5] BroadSoft, Inc. 2006. BroadWorks Redundancy Guide, Release 14.0. Available  
from the BroadSoft KnowledgeBase at www.broadsoft.com/KnowledgeBase.  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 26 OF 25  
 

Haier Clothes Dryer HDY60M User Manual
Haier Microwave Oven MA 2270EGC User Manual
Hasbro Games 20574 20570 User Manual
Heat Glo LifeStyle Boiler COSMO I30 User Manual
HP Hewlett Packard Landscape Lighting model 3585d User Manual
Hypertec Carrying Case N11018AHY User Manual
Hyundai Car Stereo System H CMD7087 User Manual
Hyundai Car Video System H LCDVD704 User Manual
IBM Personal Computer 8172 User Manual
Image Home Gym 831100430 User Manual